Herunterladen Diese Seite drucken
Siemens IMKW6-10 Installationsanleitung
Siemens IMKW6-10 Installationsanleitung

Siemens IMKW6-10 Installationsanleitung

Kabelloser magnetkontakt

Werbung

Building Technologies
Fire Safety & Security Products
IMKW6-10
Wireless Magnet Contact
Kabelloser Magnetkontakt
Contact aimant sans fil
Contacto magnético inalámbrico
Contatto magnetico via radio
Contacto magnético sem fios
Trådløs magnetkontakt
Draadloos magneetcontact
Bezdrátový magnetický kontakt
Trådlös magnetkontakt
STEP: 009914_h_--_--
Edition: 2013-01-28
CADIM: A5Q00053228
P/N 7121407 Rev. E
English
Before starting to install and work with this device, please read the Safety
Instructions
Scope of delivery (fig.1):
IMKW6-10 Wireless Magnet Contact + battery 3.6V ½ AA (a)
Magnet unit (b)
Screws: for detector (c), for magnet (d)
Plugs (e)
Jumper: for disabling the back tamper switch
Installation
Removing the front cover (Fig. 2-3)
Insert a screwdriver in the slot of the snap release and push gently, until the
front cover is disengaged and you hear the opening click (Fig. 2).
Lift the Printed Circuit Board (Fig. 3b).
Mounting the base (Fig. 4)
Pay attention to the guidelines in the Installer Manual for mounting the
IMKW6-10.
Break out the desired holes on the base for proper installation.
Mount the base to a fixed part of a door or window.
Install the Printed Circuit board back into the base.
Use only the screws and plugs supplied.
Setting operation Mode (external contacts)
The unit can be configured for connecting one or more external contacts (NC) in
series. This connection is protected by End Of Line 8.2k Ohm series resistor. The
external wiring can be up to 15 m.
There are 3 operation modes for the IMKW6-10. The unit learns the mode of
operation during power-up (insertion of the battery).
1
(EN)
(DE)
(FR)
(ES)
1xb
2xc
(IT)
(PT)
(NO)
(NL)
(CS)
4
(SV)
Mode
Internal contact only
External contact only
Internal and external
Disable back tamper switch
The back tamper of the unit can be deactivated by inserting a jumper (Fig.
3a).
When the bypass jumper is set, the unit complies with EN50131 security
grade 1. W hen the jumper is NOT set, the unit complies with EN50131
security grade 2.
Mounting the magnet (Fig. 5)
Mount the magnet unit near the markings of the base to the movable
part of a door or window.
Installing the battery (Fig. 6-7)
Risk of explosion if battery is replaced by an incorrect type. Use only
batteries delivered by the supplier.
Insert the battery according polarity (-) (+) (Fig. 6).
Place the cover by inserting back in the appropriate closing pin.
Screw in the retaining screw (Fig. 7).
Enrolment
To enrol the IMKW6-10 on the SiWay panel/gateway, please follow the
instructions of the corresponding installation/configuration manual.
Testing
Alarm transmission test
Select the "Walk Test Mode" in the control panel as described in the
installation/configuration manual in order to avoid a real alarm
transmission.
Remove the magnet:
The control panel will indicate each alarm transmission received.
Replace the magnet:
The alarm message disappears.
2
1xa
2xc 1xd 2xd 2xe
5
Setting at power-up
External Contact
Internal Contact
open
close
Close with 8.2k EOL
open
Close with 8.2k EOL
close
3
a
b
6
7
Installation Instruction
Technical Data
Data Protocol
SiWay
Wireless – range
up to 300 m at open space
Frequency band
868 MHz
Identification
Unique ID serial number – 24 bit
Alarm, Tamper, Supervision,
Event Transmission
Low Bat (at 2.4 V)
Supervision Timing
6~7 minutes (random)
Detection Method
Internal Reed Switch and External contacts
Wood/Plastic
Metal (Iron)
Open/close distances (Fig. 5a)
Metal (Aluminum)
Concrete
Battery
Lithium. 3.6 V Type: XL-050F, Size: 1/2AA
EOL resistor
8.2k
Standby ~5 A
Power Consumption
Transmission ~16 mA
Dimensions
87 x 35 x 25 mm
Weight (inc. battery)
~40 g
Environmental conditions:
Operation temperature
-10 to +50 °C
Storage temperature
-20 to +60 °C
Humidity (EN60721)
< 85% r.h., non condensing
Housing protection EN60529,
IP41 / IK02
EN50102
Siemens Security Products hereby declares that this product is in compliance with
the essential requirements and other relevant provisions of Directive 1999/5/EC on
Radio and Telecommunications Terminal Equipment (R&TTE) and 2004/108/EC on
Electromagnetic Compatibility (EMC).
The EC Declaration of Conformity is available from your Siemens sales office or:
Siemens AB, Security Products, Englundavägen 7, SE-171 24 Solna, Sweden
EN50131-2-6, Security Grade 2, Environmental Class II certified by:
For more detailed instruction please refer to the manuals of the respective control
panel or gateway.
Close
Open
<16 mm
>21 mm
<6 mm
>10 mm
<9 mm
>13 mm
<15 mm
>20 mm

Werbung

loading

Inhaltszusammenfassung für Siemens IMKW6-10

  • Seite 1 EN50102 Alarm transmission test There are 3 operation modes for the IMKW6-10. The unit learns the mode of Siemens Security Products hereby declares that this product is in compliance with Select the “Walk Test Mode” in the control panel as described in the operation during power-up (insertion of the battery).
  • Seite 2 Protección carcasa EN60529, IP41 / IK02 Existen 3 modos operativos para IMKW6-10. La unidad establece la Para registrar la unidad IMKW6-10 en el SiWay o la puerta de enlace, siga correspondencia del modo de operación durante el encendido (inserción de la EN50102 las instrucciones del manual de instalación/configuración correspondiente.
  • Seite 3 Para registar o IMKW6-10 no painel/gateway SiWay, por favor, siga as Humidade (EN60721) < 85% r.h., sem condensação Existem 3 modos de operação para o IMKW6-10. O modo de operação é instruções do manual de instalação/configuração correspondente. Protecção tampa EN60529, adquirido pelo aparelho durante a colocação sob tensão (inserção da pilha).
  • Seite 4 Pokud chcete zaregistrovat IMKW6-10 do panelu/brány SiWay, postupujte Vlhkost (EN60721) < 85% relativ. vl kosti, bez kondenzace K dispozici jsou 3 provozní režimy pro IMKW6-10. Jednotka se p izp sobí režimu podle pokyn v p íslušném návodu na instalaci/konfiguraci. Krytí dle EN60529, EN50102 IP41 / IK02 provozu b hem p ipojení...