troubleshooting

Breakdown
The appliance no longer
works
The interior lighting does
not work.
Temperature in the
refrigerator is too high or
too low
The appliance is working
continuously.
There is water in the
lower section of the
refrigerator.
Unusual or loud noises
During normal use of the cooling appliance, different types of noises can occur that do not have any effect on the correct
operation of the freezer.
Noises that can be easily remedied:
• Noise due to the fact that the appliance is not level – position the appliance using the front adjustable feet. If necessary,
place soft material under the rear wheels, particular in case of a tiled floor.
• Friction against other furniture – move the appliance.
• Grinding of drawers or shelves – remove the shelf or drawer and then place it back.
• Noise of colliding bottles – place the bottles apart.
Noises that can be heard during normal use of the appliance are caused by the operation of the thermostat, compressor
(activation), cooling system (shrinkage and expansion of the material under the influence of temperature differences and
flow of cooling liquid).
Cause
There is an interruption in the
power supply.
The lamp is defective or the plug
is not in the socket.
Wrong setting of the thermostat.
The ambient temperature is
higher or lower than the
temperature indicated in the
table with technical data.
The appliance is located in direct
sunlight or near a heat source.
A too large amount of hot food
has been placed in the appliance
at once.
The ventilation at the rear of the
appliance is hindered.
The door of the refrigerator is
opened too frequently or remains
open for too long.
The door is not closed properly.
The compressor does not work
often enough.
The door rubber is loose.
Wrong setting of the thermostat.
The opening of the defrost water
drain is clogged.
The ventilation within the cooler
section is hindered.
The appliance is not level and
stable.
The appliance is standing against
something.
Solution
- check that the plug is properly inserted in the socket
- check that the power cable is not damaged
- check that there is voltage on the socket by connecting a
different appliance, such as a night lamp
- check that the appliance is on by setting the thermostat
higher than 0
Check the solutions above or have the lamp replaced.
- turn the thermostat to a different position
The appliance is intended for operation in an
ambient temperature indicated in the table with technical
data supplied with the appliance.
Change the location of the appliance according to the
information in the instruction manual.
Wait 72 hours until the products are frozen. The
temperature in the appliance will return to the required
level.
Keep the appliance 10 cm away from the walls, for
sufficient ventilation.
Open the door less often and/or reduce the time that the
door remains open.
Make sure the foods are placed in such a way that they do
not hinder the door when it is being closed.
Check that the ambient temperature is not lower than the
range of the climate class.
Fasten the door rubber or have it replaced.
- turn the thermostat to a higher position
Clean the opening of the defrost water drain by means of
the skewer.
Check that the food does not make contact with the rear
wall of the refrigerator.
Level the appliance with the adjustable feet.
Place the appliance in such a way that it is not standing
against anything.