4.4. Search for live wires
a.
The warning for live wires is displayed in every mode.
1.
The detector can detect live wires with 50 Hz or 60 Hz. Other
live wires cannot be displayed. Press the "3" key twice to
search for live wires. At this point the warning symbol "g"
appears in the display and the LED display "1" lights up green.
2.
Position the measuring device on any surface and move it
around there. If the measuring device comes close to a live
wire, the display of the measuring indicator "j" increases and
the signal tone sounds with a rapid sequence of tones. Move
the measuring device over the surface again to find the center
of the searching line. In the position with maximum display, the
live wire is below the middle of the sensor. At this point, the "i"
will appear on the display and the acoustic signal will sound
with a quick sequence of tones. In addition, the LED display "1"
lights up red. When the measuring device moves away from
the live wire, the display decreases.