Note: When scanning for metal objects, the display will show
"e" (distance value) in the display. If the measured
objects are the standard steel rods with a diameter of 20mm
and the steel rod is relatively parallel to the detector, the
accuracy of the value is best. The distance value is only used
as a general reference value.
Note: For reinforcing steel mesh and steel in the examined
base material, a display is given over the entire surface of the
measurement indicator "i". It is typical for reinforcing steel mesh
that the symbol "k" for magnetic metal is shown on the display
directly above the iron bars, while the symbol "c" for non-
magnetic metal is shown between the iron bars.
Note: Switch on the measuring tool. After a short self-test, the
detector is ready for use. When the measuring tool has the
following condition, the measuring tool needs to be calibrated.
a.
When you switch on the tracking device, it will calibrate itself. In
the event of faults, switch the device off and on again so that
the measuring device can calibrate itself once and the faults
can be eliminated.
b.
At extreme temperatures or temperature fluctuations the
accuracy of the tracking device is faulty and that meter needs
to be calibrated. The calibration method is:
Position the Measuring device in an environment without
metal and without strong magnetic field disturbances. Press the
metal mode button "3" for approx. 2 seconds. Now the detector
will do a brief self-examination. The LED display "1"lights up
green and indicates the self-calibration.