Herunterladen Inhalt Inhalt Diese Seite drucken

Nordpeis Q-34AL Montageanleitung Seite 21

Heizeinsatz
Vorschau ausblenden Andere Handbücher für Q-34AL:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

INDEX
1. Prior to assembling the insert
Chimney Draught
Shared flue gas system
Air Supply
2. Technical Information
3. Distance to combustible material
4. Assembly
Removing the insert from the pallet
Operational control
Pulley radiation shield
Self closing door
Cleaning the glass
Radiation shields
Thermotte
Powerstone (accessory)
Flue collar and connection
Painting the surround
5. Lighting the fire for the first time
6. Maintenance
Cleaning and inspection
Ashes
Thermotte™
Door and glass
7. Warranty
8. Advice on lighting a fire
Some advice in case of combustion problems
1. Prior to assembling the insert
All our products are tested according to the latest
European requirements and also to the Norwegian
standard NS 3058 and NS 3059, which include particle
tests. However, several European countries have local
regulations for installation of fireplaces, which change
regularly. It is the responsibility of the client that these
regulations are complied with in the country/region
where the fireplace is installed. Nordpeis AS is not
responsible for incorrect installation.
Important to check
(please note that this list is not exhaustive):
distance from firebox to combustible/flammable
materials
insulation materials/requirements between
fireplace surround and back wall
size of floor plates in front of fireplace if required
flue connection between firebox and chimney
insulation requirements if flue passes through a
flammable wall
Chimney draft
Compared with older models, the clean burning inserts
of today put significantly higher demands on the
chimney. Even the best insert will not work properly
if the chimney does not have the right dimensions or
9
is not in good working order. The draught is mainly
9
controlled by gas temperature, outside temperature, air
9
supply as well as the height and inner diameter of the
9
chimney. The diameter of the chimney should never
10
be less than that of the flue/chimney collar. For draft
requirements at nominal heat output, see technical
10
table
11
The draught increases when:
11
The chimney becomes warmer than the outside air
11
The active length of the chimney over the hearth
11
increases
11
Good air supply to the combustion
11
11
It can be difficult to obtain the right draught conditions
11
in case the chimney is too large relative to the insert,
11
as the chimney does not heat up well enough. In
11
such cases you may want to contact professional for
11
evaluation of possible measures. Draught that is too
12
strong can be controlled with a damper. If necessary,
contact a chimney sweeper.
12
12
Shared flue gas sytem
12
12
Appliance can be connected to shared flue gas pipe
13
sytem.
13
13
Warning! In case of the appliance connected to
shared flue gas pipe system - the Self Closing
15
Door system must be operational. See Para-
graph 4. Assembly - Self Closing Door.
Air supply
A set for fresh air supply is available as an accessory.
This will ensure that the air supply to the combustion
chamber is less affected by ventilation systems, kitchen
fans and other factors which can create a down-draught
in the room. In all new constructions, we strongly
recommend the product is designed and prepared
for direct supply of outside air. In older houses also,
the use of fresh air supply set is also recommended.
Insufficient air supply can cause poor draught and
thereby low combustion efficiency and the problems this
entails: soot stains on the glass, inefficient utilisation of
the wood and a soot deposits in the chimney.
Warning! Keep the air intakes, supplying
combustion air, free from blockage.
Warrning! Extractor fans when operating
in the same room or space as the appliance
may cause problem.