Digitale messuhr 0-10mm

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

O P E R A T I N G I N S T R U C T I O N S
Digital dial gauge 0-10mm
Item-No. 82 15 72
Intended use
The digital dial gauge is used to measure heights or height differences on objects or surfaces to be
measured in production and development.
Any other use than that described above, could lead to damage to this product and involves the risk of
short circuits, fire, electric shock, etc.
Always observe the safety notes included in these operating instructions.
If you transfer this product to third persons, also pass on these operating instructions!
This product complies with the applicable National and European requirements. All names of compa-
nies and products are the trademarks of the respective owner. All rights reserved.
Package Contents
• Digital dial gauge
• Battery (might already be inserted)
• Operating Instructions
Safety Instructions
Prior to starting up the product read the entire operating instructions, they contain
important information on the correct operation. The warranty will be void in the
event of damage caused by failure to observe these safety instructions! We do not
assume any liability for any consequential damage!
Nor do we assume any liability for material and personal damage caused by
improper use or non-compliance with the safety instructions! The warranty will be
void in such cases.
• For safety reasons, any unauthorised conversion and/or modification to the product is
not permitted.
• The dial gauge consists of electrically conductive metal. For this reason, the dial gauge
may not be used for measurements on live cables or objects; danger to life from elec-
tric shock! Besides, the object to be measured may be damaged by a short circuit!
• Do not apply the dial gauge on sensitive objects or surfaces since the sharp edges may
cause scratch marks on the object to be measured.
• The product must not get damp or wet.
• Do not allow children to play with the device.
• Do not leave packing materials unattended. They may become dangerous playthings
for children.
• Handle the product with care, it can be damaged by impacts, blows, or accidental
drops, even from a low height.
Controls
1 Battery compartment
2 Key „mm/in" to switch the measure-
ment unit („mm" or „inch")
3 "ON/OFF" button to turn on/off
4 LCD display
5 Data output (under the cover)
6 Key „ZERO" for zero position
7 Clamping shaft
8 Replaceable test prod
General Battery Instructions
• Keep batteries out of the reach of children.
• Do not leave batteries lying around in the open; there is a risk of them being swallowed by children
or domestic animals. If swallowed, consult a doctor immediately.
• Leaking or damaged batteries can lead to caustic burning of the skin. Therefore, use suitable protec-
tive gloves.
• Batteries/rechargeable batteries must not be short-circuited, opened or thrown into a fire. There is a
risk of explosion!
• Conventional batteries must not be recharged. Risk of explosion!
• Please pay attention to the correct polarity (plus/+ and minus/-) when inserting the battery.
Inserting/Replacing the Batteries
www.conrad.com
The battery compartment (1) for a battery of type CR2032 is located on the left side of the dial gauge.
Remove the battery holder from the dial gauge carefully. Insert a battery in such a way that the plus
pole ("+") points outwards in direction of the LC display.
Version 10/09
The battery must be replaced if the contrast in the display starts to fade or the dial gauge can no longer
°
be switched on.
Data output
The measured data can be transferred to a PC via the data output (5) through a suitable connection
cable and a suitable software (not included in the delivery, can be acquired optionally as accessory).
For this, observe the operating manual for the connection cable/software.
Operation
• Clean the surface of the test prod carefully prior to each measuring procedure, otherwise you may
get faulty measurements.
• Switch the dial gauge on or off by using the button „ON/OFF" (3).
• With the button „ZERO" (6) the value display can be reset to „0". Thus, both an absolute measure-
ment and a relative measurement (difference) are possible.
• The key „mm/inch" (2) is used to switch between the measurement units „mm" and „inch".
• Pay attention that the dial gauge is not attached in a wedged or inclined fashion since this may lead
to faulty measurements. Ideally, the shaft of the dial gauge must be in a right angle to the measur-
ing surface.
• A spring holds the measuring shaft always on the surface to be measured. Therefore, do not release
the measuring shaft jerkily but place it slowly and carefully onto the surface to be measured. Release
the measuring shaft afterwards. If you release the measuring shaft jerkily, the mechanics inside the
dial gauge may be damaged!
Maintenance and Care
Clean the dial gauge with a dry, clean and soft cloth. Keep water and other liquids away from the dial
gauge since they may lead to corrosion. If required, you can clean the surfaces of the clamping shaft
and the test prod with a suitable oil. Wipe off the surfaces thoroughly afterwards.
Disposal
a) Product
b) Batteries and rechargeable batteries
The end user is legally obliged (Battery Regulation) to return used batteries and rechargeable batter-
ies. Do not dispose of used batteries in household waste!
You therefore fulfill your statutory obligations and contribute to the protection of the environment.
Technical Data
Power supply ..................1 battery of type CR2032
Battery life ........................approx. 1 year
Measurement range ........0-10mm (0-0.5")
Definition ..........................0.01mm (0.0005")
Weight..............................99.5g (without battery
Dimensions ......................118 x 64 x 32mm (H x W x D)
Test prod..........................Thread M2.5
© Copyright 2009 by Conrad Electronic SE.
In order to save the battery, switch the dial gauge off if you don't need it.
Please dispose of the product, when it is no longer of use, according to the current
statutory requirements.
Contaminated batteries/rechargeable batteries are labelled with these symbols to indi-
cate that disposal in the domestic waste is forbidden. The symbols for the relevant heavy
metals are: Cd=cadmium, Hg=mercury, Pb=lead (the labelling is visible on the battery/
rechargeable battery e.g. under the refuse bin symbol shown on the left).
You can dispose of your used batteries/rechargeable batteries free of charge at your
community's collection point or any place where batteries/rechargeable batteries are
sold!
These operating instructions are a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240
Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or
the capture in electronic data processing systems require the prior written approval by the editor.
Reprinting, also in part, is prohibited.
These operating instructions represent the technical status at the time of printing. Changes in
technology and equipment reserved.
64mm
61mm
118mm
Ø8mm
42mm
M2.5