6.2 Ambient conditions

Type:
Ambient temperature
Storage temperature
Humidity
Max. height above sea level
Outdoor installation
Mechanical environments
Table 7 | Ambient conditions

6.3 Approvals*

Approval:
Approval number:
PED
QA/QAe: CE-0085BM0186
ATEX
II 2G Ex h IIC T4 Gb
8000310657
IECEx
Ex h IIC T4 Gb
IECEx TUR 16.0043x
Table 8 | Approvals
ATEX/IECEx legend:
Marking of explosion protection
II
Equipment group: industrial (mining excluded)
2
Equipment category 2 (Zone 1)
G
Potentially explosive gas atmospheres
h
Type of ignition protection: mechanical explosion protection
IIC
Explosion group for gases
T4
Temperature class
Gb
Equipment protection level
* The marking on the device shall be applicable.
73025026a
© Elster GmbH | All rights reserved. Subject to modification
QA
-10°C to +60°C
-10°C to +60°C
0 to 80% RH
2000 m
Approval body:
DVGW Cert GmbH | Germany
Josef-Wirmer-Straße 1-3 | 53123 Bonn
TÜV Nord AG
Am TÜV 1 | 30519 Hannover | Germany
TÜV Rheinland Industrieservice GmbH
Am Grauen Stein | 51105 Köln | Germany
QAe
0°C to +50°C
0°C to +50°C
Yes
M1
Honeywell