Turbinenradgaszähler und quantometer
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 34
L-Bus
 The pulse outputs are open collector outputs – there is no internal
limitation of current. Depending on the level of the external supply voltage
applied, a serial resistor must be inserted between the voltage source and
pulse output.
 The operating current during a pulse must not exceed 27 mA.
PLC example circuit:
 One of the most frequent applications
is for feedforwarding the output pulse
to a PLC.
Pulse outputs (L-BUS module only)
 Max. input voltage: 30 V
 Max. input current: 27 mA
 Voltage drop at active output: max.
2 V/27 mA
 Current across inactive output: max.
5 µA/30 V
 Max. reverse voltage without destroying
the outputs: 6 V
 Pulse duration: min. 25 ms
 Interpulse period: min. 25 ms
 Max. pulse repetition frequency: 20 Hz
Standard pulse values:
Nominal size
[DN]
25
10 pulses
40, 50
1 pulse
80, 100, 150
1 pulse
Table 3 | L-Bus pulse value
73025026a
© Elster GmbH | All rights reserved. Subject to modification
Pulse value
for 1 m³
for 1 pulse
1 f³
10 f³
100 f³
Fig. 9 | L-Bus connection