Herunterladen Inhalt Inhalt Diese Seite drucken

Ambient Conditions; Approvals - Honeywell RABO Betriebsanleitung

Drehkolbengaszähler
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 35
Connections
DN
32
40
50
80
100
150
Table 9 | Connections

5.2 Ambient conditions

Ambient temperature
Storage temperature
Humidity
Max. height above sea level
Outdoor installation
Mechanical environments
Table 10 | Ambient conditions

5.3 Approvals

Approval:
Approval number:
MID
DE-12-MI002-PTB001
PED
CE-0085CN0022
ATEX
II 2G Ex h IIC T4 Gb
557/Ex-Ab 2664/16
IECEx
Ex h IIC T4 Gb
IECEx TUR 16.0042X
Table 11 | Approvals
ATEX/IECEx legend:
Marking of explosion protection
II
Equipment group: industrial (mining excluded)
2
Equipment category 2 (Zone 1)
G
Potentially explosive gas atmospheres
h
Type of ignition protection: mechanical explosion protection
IIC
Explosion group for gases
T4
Temperature class
Gb
Equipment protection level
730xxxxxe
© Elster GmbH | All rights reserved. Subject to modification
Pressure rating
PN 16 / Class 150
PN 16 / Class 151
PN 16 / Class 152
PN 16 / Class 153
PN 16 / Class 154
PN 16 / Class 155
-25°C to +70°C
-40 °C to +70°C
0 to 80% RH
2000 m
Yes
M1
D
k
100/88.90
4 x M16 / 4 x M12
110/98.60
4 x M16 / 4 x M12
125/120.70
4 x M16 / 4 x M16
160/152.40
8 x M16 / 4 x M16
180/190.50
8 x M16 / 8 x M16
240/241
8 x M20 / 8 x M20
Approval body:
Physikalisch-Technische Bundesanstalt (PTB)
Bundesallee 100 | 38116 Braunschweig
Germany
DVGW Cert GmbH | Germany
Josef-Wirmer-Straße 1-3 | 53123 Bonn
TÜV Rheinland Industrieservice GmbH
Am Grauen Stein | 51105 Köln | Germany
TÜV Rheinland Industrieservice GmbH
Am Grauen Stein | 51105 Köln | Germany
Honeywell
D
i
29

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis