Bedienungs- und Montageanleitung
Multifunktionaler Aufputzfühler bzw. Messumformer
für Feuchte, Temperatur,
Luftgüte (VOC) und CO
- Gehalt,
2
kalibrierfähig, mit aktivem ⁄ schaltendem Ausgang
G
Operating Instructions, Mounting & Installation
Multifunctional on-wall sensors and measuring transducers
for humidity, temperature,
air quality (VOC) and CO
2
calibratable, with active ⁄ switching output
F
Notice d'instruction
Sonde (transmetteur) pour montage en saillie
multifonctionnelle, pour l'humidité, la température,
la qualité d'air (COV) et de teneur en CO
étalonnable, avec sortie active ⁄ tout ou rien
r
Руководство по монтажу и обслуживанию
Мультифункциональный датчик для открытой установки ⁄
измерительный преобразователь,
для измерения влажности, температуры,
качества воздуха (VOC) и содержания CO
калибруемый, с активным ⁄ релейным выходом
S+S REGELTECHNIK GMBH
PIRNAER STRASSE 20
90411 NÜRNBERG ⁄ GERMANY
FON +49 (0) 911 ⁄ 5 19 47- 0
FAX +49 (0) 911 ⁄ 5 19 47- 70
mail@SplusS.de
www.SplusS.de
- W ⁄ ALQ - CO
2
⁄ AFTM - LQ - CO
2
content,
,
2
,
2
- W
2
2
Herzlichen Glückwunsch!
Sie haben ein deutsches Qualitätsprodukt erworben.
Congratulations!
You have bought a German quality product.
Félicitations !
Vous avez fait l'acquisition d'un produit allemand de qualité.
Примите наши поздравления !
Вы приобрели качественный продукт, изготовленный в Германии.
AFTM - CO
2
AFTM - LQ - CO
2

Werbung

Inhaltsverzeichnis
loading

Inhaltszusammenfassung für S+S REGELTECHNIK AERASGARD ACO2-W

  • Seite 1 Мультифункциональный датчик для открытой установки ⁄ измерительный преобразователь, для измерения влажности, температуры, качества воздуха (VOC) и содержания CO калибруемый, с активным ⁄ релейным выходом S+S REGELTECHNIK GMBH Herzlichen Glückwunsch! Sie haben ein deutsches Qualitätsprodukt erworben. PIRNAER STRASSE 20 Congratulations! 90411 NÜRNBERG ⁄ GERMANY You have bought a German quality product.
  • Seite 2 D G F r AFTM - CO AERASGARD ®  AFTM - LQ - CO AERASGARD ®  AFTM - CO Maßzeichnung Dimensional drawing AFTM - LQ - CO Plan coté Габаритный чертеж SF -K Kunststoff-Sinterfilter (Standard) plastic sinter filter (standard) Filtre fritté en matière synthétique (standard) сменный...
  • Seite 3: Technische Daten

    ® AERASGARD - W ⁄ ALQ - CO - W ⁄ AFTM - CO ⁄ AFTM - LQ - CO Rev. 2017 - V20 DE Der wartungsfreie mikroprozessorgesteuerte AERASGARD ® AFTM - LQ - CO bzw. ACO - W ⁄ ALQ - CO - W ist zur Aufputzmontage und dient zur Erfassung aller für ein Raumklima relevanten Messgrößen.
  • Seite 4 ® AERASGARD - W ⁄ ALQ - CO - W ⁄ AFTM - CO ⁄ AFTM - LQ - CO Rev. 2017 - V20 DE TECHNISCHE DATEN (Fortsetzung) Relais-Ausgang: mit potentialfreiem Wechsler (24 V), 1 A ohmsche Last (Zuordnung über DIP-Schalter wählbar) Umgebungstemperatur: –10...+60 °C Ansprechzeit:...
  • Seite 5 ® AERASGARD - W (mit Display) ⁄ ALQ - CO - W ⁄ AFTM - CO ⁄ AFTM - LQ - CO Rev. 2017 - V20 DE AFTM - LQ - CO Schaltbild OFFSET CO ² VOC °C r.H. 1 2 3 4 5 6 7 8 9 CO ²...
  • Seite 6 ® AERASGARD - W (ohne Display) Rev. 2017 - V35 DE (KCO2 -TYR1) Schaltbild ON DIP Zero 1 2 3 4 OFFSET 13 11 12 1 2 3 DIP-Schalter - Gehalt DIP 1 0...2000 ppm (default) 0...5000 ppm - Nullpunktautomatik DIP 3 deaktiviert aktiviert (default)
  • Seite 7: Montage Und Installation

    Montage und Installation ACHTUNG !  Die minimale CO - Konzentration von Außenluft beträgt in begrünten, industrie armen Gegenden ca. 350 ppm (Ausgangs spannung = 1,75 V bei MB = 2000 ppm bzw. 0,7 V bei MB = 5000 ppm). Der Gas austausch im Sensorelement erfolgt durch Diffusion. Je nach Konzentrationsänderung und Strömungs geschwindigkeit der Luft in Sensor umgebung kann die Reaktion des Gerätes auf die Konzentrationsänderung verzögert auftreten.
  • Seite 8 Montage und Installation Inbetriebnahme Nach dem Einschalten des Gerätes erfolgen ein Selbsttest und die Temperierung. Dieser Vorgang dauert je nach Umgebungsbedingun gen 30 - 50 Minuten, in dieser Zeit weicht die ausgegebene Analog spannung vom tatsächlichen Messwert ab. Schaltpunkteinstellung Über das Potentiometer SET kann ein Schaltpunkt zwischen 10 % und 95 % des des Messbereichs gewählt werden.
  • Seite 9: Wichtige Hinweise

    Wichtige Hinweise – Dieses Gerät darf nur in schadstofffreier, nicht kondensierender Luft, ohne Über- oder Unterdruck am Sensorelement eingesetzt werden. – Bei Aussen- und Kanalfühlern schützt der Sinterfilter des Sensorelementes den Feuchtesensor vor eventuellen Staub belastungen. Dieser Filter sollte bei Verunreinigung ⁄ Verschmutzung regelmäßig gewartet werden. –...
  • Seite 10: Technical Data

    ® AERASGARD - W ⁄ ALQ - CO - W ⁄ AFTM - CO ⁄ AFTM - LQ - CO Rev. 2017 - V20 GB The maintenance-free, microprocessor-controlled AERASGARD ® AFTM - LQ - CO or ACO - W ⁄ ALQ - CO - W is designed for on-wall installation and is used to monitor all measurands of relevance to the climate inside a room.
  • Seite 11 ® AERASGARD - W ⁄ ALQ - CO - W ⁄ AFTM - CO ⁄ AFTM - LQ - CO Rev. 2017 - V20 GB TECHNICAL DATA (continued) Relay output: with potential-free changeover contact (24 V), 1 A ohmic load (assignment selectable via DIP switches) Ambient temperature: –10...+60 °C...
  • Seite 12 ® AERASGARD - W (with display) ⁄ ALQ - CO - W ⁄ AFTM - CO ⁄ AFTM - LQ - CO Rev. 2017 - V20 GB Schematic diagram AFTM - LQ - CO OFFSET CO ² VOC °C r.H. 1 2 3 4 5 6 7 8 9 CO ²...
  • Seite 13 ® AERASGARD - W (without display) Rev. 2017 - V35 GB (KCO2 -TYR1) Schematic diagram ON DIP Zero 1 2 3 4 OFFSET 13 11 12 1 2 3 DIP switch content DIP 1 0...2000 ppm (default) 0...5000 ppm - automatic zero point DIP 3 deactivated activated (default)
  • Seite 14 Mounting and Installation ATTENTION!  The minimum CO concentration of outdoor air amounts to approx. 350 ppm (output voltage = 1.75 V at MR = 2000 ppm or 0.7 V at MR = 5000 ppm) in leafy, hardly industrialised areas. Gas inter-exchange in the sensor element happens by diffusion. Depending on the changes to the concentration and the flow velocity of the air surrounding the sensor, the reaction of the device to the change of concentration may take place with a delay.
  • Seite 15 Mounting and Installation Putting in operation After switching on the device, a self-test and tempering period follows. This procedure takes 30 - 50 minutes,depending on the ambient conditions. During this time the output analogue voltage differs from the actual measured value. Switching point setting A switching point between 10 % and 95 % of the measuring range can be selected using the SET potentio- meter.
  • Seite 16 General notes – This device may only be used in pollutant-free non-precipitating air without above-atmospheric or below-atmospheric pressure at the sensor element. – On outdoor and duct sensors, the sinter filter of the senor element protects the humidity sensor against potential dust exposure. In case of pollution ⁄...
  • Seite 17: Caractéristiques Techniques

    ® AERASGARD - W ⁄ ALQ - CO - W ⁄ AFTM - CO ⁄ AFTM - LQ - CO Rev. 2017 - V20 FR La sonde AERASGARD ® AFTM - LQ - CO ou ACO - W ⁄ ALQ - CO - W commandée par microprocesseur sans entretien est conçue pour un montage en saillie et sert à...
  • Seite 18 ® AERASGARD - W ⁄ ALQ - CO - W ⁄ AFTM - CO ⁄ AFTM - LQ - CO Rev. 2017 - V20 FR CARAC TÉRISTIQUES TECHNIQUES (Suite) Sortie relais : avec inverseur libre de potentiel (24 V), charge ohmique 1 A (affectation sélectionnable via interrupteur DIP) Température ambiante : –10...+60 °C...
  • Seite 19 ® AERASGARD - W (avec écran) ⁄ ALQ - CO - W ⁄ AFTM - CO ⁄ AFTM - LQ - CO Rev. 2017 - V20 FR Schéma de raccordement AFTM - LQ - CO OFFSET CO ² VOC °C r.H. 1 2 3 4 5 6 7 8 9 CO ²...
  • Seite 20 ® AERASGARD - W (sans écran) Rev. 2017 - V35 FR (KCO2 -TYR1) Schéma de raccordement ON DIP Zero 1 2 3 4 OFFSET 13 11 12 1 2 3 Interrupteur DIP Teneur en CO DIP 1 0...2000 ppm (default) 0...5000 ppm Point zéro automatique CO DIP 3...
  • Seite 21: Montage Et Installation

    Montage et installation ATTENTION !  La teneur minimale en CO de l'air extérieur dans des régions vertes à faible degré d'industrialisation est de l'ordre 350 ppm (tension de sortie = 1,75 V à MB = 2000 ppm, resp. 0,7 V à MB = 5000 ppm). L'échange de gazdans l'élément capteur s'effectue par diffusion. En fonction de la variation de la concentration et de la vitesse d'écoulement de l'air dans l'environnement du capteur, la réaction de l'appareil à...
  • Seite 22 Montage et installation Mise en service Après la mise en marche de l’appareil, celui-ci effectue un autocontrôle et l’équilibrage de température. En fonction des conditions d'environnement, cette opération dure entre 30 - 50 minutes, pendant ce temps la tension analogique émise diffère de la valeur de mesure réelle. Réglage du point de commutation Un point de commutation entre 10 % et 95 % de la plage de mesure peut être sélectionné...
  • Seite 23: Généralités

    Généralités – Cet appareil ne doit être utilisé que dans un air non pollué, sans risque de condensation, sans risque de surpression ou dépression sur l’élément sensible. – Dans le cas des sondes extérieures et des sondes pour montage en gaine, le filtre fritté de l’élément sensible protège la sonde d’humidité contre la pénétration des particules de poussières.
  • Seite 24: Технические Данные

    ® AERASGARD - W ⁄ ALQ - CO - W ⁄ AFTM - CO ⁄ AFTM - LQ - CO Rev. 2017 - V20 RU Не нуждающийся в техническом обслуживании, управляемый микропроцессором датчик AERASGARD ® AFTM - LQ - CO или ACO - W ⁄ ALQ - CO предназначен...
  • Seite 25 ® AERASGARD - W ⁄ ALQ - CO - W ⁄ AFTM - CO ⁄ AFTM - LQ - CO Rev. 2017 - V20 RU ТЕ ХНИЧЕСКИЕ Д АННЫЕ (продолжение) Релейный выход: беспотенциальный переключающий (24 В), омическая нагрузка 1 А (присваивается с помощью DIP-переключателя) Температура...
  • Seite 26 ® AERASGARD - W (c дисплеем) ⁄ ALQ - CO - W ⁄ AFTM - CO ⁄ AFTM - LQ - CO Rev. 2017 - V20 RU Схема подключения AFTM - LQ - CO OFFSET CO ² VOC °C r.H. 1 2 3 4 5 6 7 8 9 CO ²...
  • Seite 27 ® AERASGARD - W (без дисплея) Rev. 2017 - V35 RU (KCO2 -TYR1) Схема подключения ON DIP Zero 1 2 3 4 OFFSET 13 11 12 1 2 3 DIP-переключатели Анализатор углекислого газа DIP 1 0...2000 млн (по умолчанию) 0...5000 млн Автоматическая калибровка нуля CO DIP 3 выключена...
  • Seite 28: Монтаж И Подключение

    Монтаж и подключение ВНИМАНИЕ!  Минимальная концентрация CO в наружном воздухе в озелененных районах с малым количеством промышленных объектов составляет прибл. 350  млн (выходное напряжение = 1,75  В при диапазоне измерения 2000  млн или 0,7  В при диапазоне измерения 5000  млн ).
  • Seite 29: Напряжение Питания

    Монтаж и подключение Запуск в эксплуатацию После включения прибора начинается самотестирование и терморегулирование. Этот процесс длится от 30 до 50  минут в зависимости от условий окружающей среды; в это время выходное аналоговое напряжение отличается от измеренного значения. Настройка порога переключения Порог...
  • Seite 30 Указания к продуктам – Данный прибор допускается применять только в воздухе без конденсата и вредных веществ, при отсутствии пониженного или повышенного давления вблизи чувствительного элемента. – В случае датчиков для наружной и канальной установки защита чувствительного элемента датчика влажности от возможного скопления пыли обеспечивается...
  • Seite 31 Reprints, in part or in total, are only permitted with the approval of S+S Regeltechnik GmbH. La reproduction des textes même partielle est uniquement autorisée après accord de la société S+S Regeltechnik GmbH. Перепечатка, в том числе в сокращенном виде, разрешается лишь с согласия S+S Regeltechnik GmbH.
  • Seite 32 D G F r ®  AERASGARD ALQ - CO AERASGARD ®  Maßzeichnung Dimensional drawing ALQ - CO Plan coté Габаритный чертеж M16x1.5...

Inhaltsverzeichnis