Bedienungs- und Montageanleitung
Anlegetemperaturfühler ⁄ Rohranlegefühler,
incl. Spannband, mit passivem Ausgang
G
Operating Instructions, Mounting & Installation
Surface contact temperature sensors ⁄ tube contact
temperature sensors, including strap, with passive output
F
Notice d'instruction
Sonde de température à applique ⁄ sonde d'applique pour
conduites, y compris collier de serrage, avec sortie passive
r
Руководство по монтажу и обслуживанию
Датчик температуры накладной ⁄ накладной для труб,
вкл. хомут, с пассивным выходом
S+S REGELTECHNIK GMBH
PIRNAER STRASSE 20
90411 NÜRNBERG ⁄ GERMANY
FON +49 (0) 911 ⁄ 5 19 47- 0
FAX +49 (0) 911 ⁄ 5 19 47- 70
mail@SplusS.de
www.SplusS.de
ALTF 2
ALTF 02
Herzlichen Glückwunsch!
Sie haben ein deutsches Qualitätsprodukt erworben.
Congratulations!
You have bought a German quality product.
Félicitations !
Vous avez fait l'acquisition d'un produit allemand de qualité.
Примите наши поздравления !
Вы приобрели качественный продукт, изготовленный в Германии.
ALTF 2
(IP 65)
ALTF 02
(IP 54)

Werbung

Inhaltsverzeichnis
loading

Inhaltszusammenfassung für S+S REGELTECHNIK THERMASGARD ALTF2

  • Seite 1 Руководство по монтажу и обслуживанию Датчик температуры накладной ⁄ накладной для труб, вкл. хомут, с пассивным выходом ALTF 02 (IP 54) S+S REGELTECHNIK GMBH Herzlichen Glückwunsch! Sie haben ein deutsches Qualitätsprodukt erworben. PIRNAER STRASSE 20 Congratulations! 90411 NÜRNBERG ⁄ GERMANY You have bought a German quality product.
  • Seite 2: Inhaltsverzeichnis

    D G F r ALTF 2 THERMASGARD ®  ALTF 02 THERMASGARD ®  ALTF 2 Maßzeichnung ALTF 02 Dimensional drawing Plan coté Габаритный чертеж M16x1.5 M16x1.5 M12-Steckverbinder (optional auf Anfrage) M12 connector (optional on request) connecteur M12 (en option et sur demande) разъем...
  • Seite 3: Thermasgard ® Altf

    ® THERMASGARD ALTF 2 ⁄ ALTF 02 Rev. 2020 - V16 Der THERMASGARD ® ALTF 2 ist ein Rohranlegewiderstandsthermometer mit passivem Ausgang, 1x Zweileiterschaltung im schlagfesten Kunststoffgehäuse mit Schnell verschluss schrauben, incl. Spannband. Standard Der THERMASGARD ® ALTF 02 ist ein kostengünstiges Rohranlegewiderstandsthermo meter, mit passivem Ausgang, im schlagfesten Kunststoffgehäuse mit Schnappdeckel, incl.
  • Seite 4: D Allgemeine Informationen

    Allgemeine Informationen Messprinzip für HLK - (HVAC) -Temperaturfühler allgemein: Das Messprinzip der Temperaturfühler beruht darauf, dass der innen liegende Sensor ein temperaturabhängiges Widerstandssignal abgibt. Die Art des innen liegenden Sensors bestimmt das Ausgangssignal. Man unterscheidet die nachfolgenden passiven ⁄ aktiven Temperatursensoren: a) Pt 100 - Messwiderstand (nach DIN EN 60 751) b) Pt 1000 - Messwiderstand (nach DIN EN 60751) c) Ni 1000 - Messwiderstand (nach DIN EN 43 760, TCR=6180 ppm ⁄...
  • Seite 5: Achtung, Hinweis

    Montage und Inbetriebnahme Die Geräte sind im spannungslosen Zustand anzuschließen. Der Hinweise zum mechanischen Ein- und Anbau: Anschluss der Geräte darf nur an Sicherheitskleinspannung er folgen. Der Einbau hat unter Berücksichtigung der einschlägigen, für den Messort gültigen Vorschriften und Standards (wie z. B. Schweißvorschriften usw.) Folgeschäden, welche durch Fehler an diesem Gerät entstehen, sind von zu erfolgen.
  • Seite 6: Technical Data

    ® THERMASGARD ALTF 2 ⁄ ALTF 02 Rev. 2020 - V16 THERMASGARD ® ALTF 2 is a tube contact resistance thermometer with passive output, in an impact- 1x two-wire connection resistant plastic housing with quick-locking screws, incl.strap. Standard THERMASGARD ® ALTF 02 is a cost-saving tube contact resistance thermometer with passive output, in an impact-resistant plastic housing with snap-on lid, incl.strap.
  • Seite 7 General notes Measuring principle of HVAC temperature sensors in general: The measuring principle of temperature sensors is based on an internal sensor that outputs a temperature-dependent resistance signal. The type of the internal sensor determines the output signal. The following active ⁄ passive temperature sensors are distinguished: a) Pt 100 measuring resistor (according to DIN EN 60 751) b) Pt 1000 measuring resistor (according to DIN EN 60751) c) Ni 1000 measuring resistor (according to DIN EN 43 760, TCR = 6180 ppm ⁄...
  • Seite 8 Installation and Commissioning Devices are to be connected under dead-voltage condition. Devices must Notes regarding mechanical mounting and attachment: only be connected to safety extra-low voltage. Consequential damages Mounting shall take place while observing all relevant regulations and caused by a fault in this device are excluded from warranty or liability. standards applicable for the place of measurement (e.g.
  • Seite 9: Caractéristiques Techniques

    ® THERMASGARD ALTF 2 ⁄ ALTF 02 Rev. 2020 - V16 La sonde THERMASGARD ® ALTF 2 est un thermomètre d’applique à résistance pour conduites avec sortie 1 x 2 fils passive, dans un boîtier plastique résistant aux chocs avec vis de fermeture rapide y compris collier de Standard serrage.
  • Seite 10: Généralités

    Généralités Principe de mesure des sondes de température pour applications CVC (HVAC) en général: Le principe de mesure se base sur le fait que le capteur à l’intérieur génère un signal de résistance dépendant de la température. Le signal de sortie est déterminé par le type de capteur qui se trouve à l’intérieur. On distingue les capteurs de température actifs et passifs suivants: a) Pt 100 –...
  • Seite 11: Montage Et Mise En Service

    Montage et mise en service Les raccordements électriques doivent être exécutés HORS TENSION. Consignes pour l’installation mécanique : Veillez à ne brancher l’appareil que sur un réseau de très basse tension L'installation doit être effectuée en conformité avec les réglementations de sécurité.
  • Seite 12: Технические Данные

    ® THERMASGARD ALTF 2 ⁄ ALTF 02 Rev. 2020 - V16 Датчик THERMASGARD ® ALTF 2 является накладным термометром сопротивления для труб с пассивным 1x Двухпроводное подключение выходом, в ударопрочном пластиковом корпусе с быстрозаворачиваемыми винтами, вкл. хомут. стандартное Датчик THERMASGARD ®...
  • Seite 13 Указания к продуктам Общий принцип измерения для датчика температуры HLK (HVAC): Принцип измерения температуры основан на зависимости электрического сопротивления чувствительного элемента (сенсора), находящегося внутри датчика, от температуры. Выходной сигнал сопротивления определяется типом чувствительного элемента. Различают следующие пассивные ⁄ активные чувствительные элементы: а) измерительный...
  • Seite 14: Монтаж И Подключение

    Монтаж и подключение Приборы следует устанавливать в обесточенном состоянии. Подключение Указания к механическому монтажу: должно осуществляться исключительно к безопасно малому напряжению. Монтаж должен осуществляться с учетом соответствующих, действи- Повреждения приборов вследствие несоблюдения упомянутых требований тельных для места измерения предписаний и стандартов (например, не...
  • Seite 15 Reprint in full or in parts requires permission from S+S Regeltechnik GmbH. La reproduction des textes même partielle est uniquement autorisée après accord de la société S+S Regeltechnik GmbH. Перепечатка, в том числе в сокращенном виде, разрешается лишь с согласия S+S Regeltechnik GmbH.
  • Seite 16 D G F r Widerstandskennlinien für passive Temperatursensoren Resistance characteristics of passive temperature sensors Courbes caractéristiques pour capteurs de température passive Характеристики сопротивления пассивных датчиков температуры PT 100 PT 1000 Ni 1000 Ni 1000 LM235Z TK 5000 (T1) 81-210 (KP10) °...