Herunterladen Inhalt Inhalt Diese Seite drucken

Victron energy PPP-8 Anleitung Seite 19

12,8v / 8 ah – 102 wh; 12,8v / 20 ah – 256 wh; 12,8v / 30 ah – 384 wh; 12,8v / 40 ah – 512 wh;
Vorschau ausblenden Andere Handbücher für PPP-8:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 57
Peak Power Pack
Capacity
Stored energy
Battery type
Nominal voltage
No load battery drain when on
Battery drain in storage mode
Continuous output current
Maximum output current (10 s)
Short circuit trip level
Protections
Maximum input (charge) current
Recommended charging voltage
Maximum input (charge) voltage
Maximum cable cross section
Continuous output current
Maximum output current (10 s)
Short circuit trip level
Protections
Maximum input (charge) current
Recommended charging voltage
Maximum input (charge) voltage
Maximum cable cross section
Input 1: multi-purpose vehicle battery / solar charger input
Input voltage range
Input current limit
Adapter output voltage
Adapter output current
Adapter input voltage
Monitoring and control
VE.Direct port
Operating temperature range
Humidity (non condensing)
Weight
Dimensions (h x w x d) in mm
Safety
Emission, Immunity
PPP-8
PPP-20
8 Ah
20 Ah
102 Wh
256 Wh
Lithium-ion ( LiFePO4)
<13 Ah / year (< 1,4 mA)
< 6,5 Ah / year (< 0,7 mA)
Output 1: high current output
Overload / short circuit / over temperature / over discharge
n.a.
n.a.
14 V (no protection)
14,2 V (no protection)
16 mm² (screw terminals)
Output 2: auxiliary output
n.a.
n.a.
n.a.
n.a.
Overload/short circuit/over temperature/over discharge
n.a.
n.a.
n.a.
n.a.
n.a.
11 V < Vin < 25 V
Input 2: power adapter
100/240 VAC
GENERAL
Multi-functional push button with bi-colour LED
Connects to a computer (VE.Direct to USB cable needed) or a smart phone
(VE.Direct Bluetooth Smart dongle needed)
Batt. charging: 0 °C to 40 °C
Storage: -20 °C to +40 °C
(charging / discharging inhibited when outside specified temperature range)
2,2 kg
3,8 kg
190x172x90
190x172x130
STANDARDS
EN/IEC 60335-1, EN/IEC 60335-2-29, EN/IEC 62109
EN 55014-1, EN 55014-2, IEC 61000-3-2, IEC 61000-3-3, EN 50498
PPP-30
30 Ah
384 Wh
12,8 V
150 A
200 A
300 A
15 A (no
protection)
30 A
50 A
80 A
10 A (no protection)
14 V (no protection)
14,2 V (no protection)
6 mm² (screw terminals)
7 A
15 V
3 A
50/60 Hz
Batt. discharging: -20 °C to +40 °C
Max 95 %
5,4 kg
190x172x170
PPP-40
40 Ah
512 Wh
20 A (no
protection)
8,6 kg
190x172x210
1

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ppp-20Ppp-30Ppp-40

Inhaltsverzeichnis