Check the machine for correct voltage. This haze has been designed to function on a mains of either
AC100~120V/7A€AC200~240V/4A
and has been fitted with a suitable power plug for use with your local voltage. Check the
label on the unit and the power plug for the correct voltage and ensure the unit is well grounded.
Please push the DIP 11 to ON, and power switch to be 1, the power indicators on the backward will light on and at the same
time, the manual remote indicator LED will be Red, then fan starts to work, and fog is on the status of warming up. When the
Manual controller board green indicator LED is green, the fog is ready to puff smoke. Keep pressing the green button on the
Manual controller board, the fog start to puff smoke. Leave the touch with the green button, and then the fog machine will stop
puffing smoke. When operate with the Manual controller board, the fog will puff at Max smoke volume. When fog machine is on
the status of ready to puff smoke, if press the CONTINUOUS button on the Manual controller board to puff smoke continuously,
with adjust wheel of volume to adjust the output of smoke volume. Release the CONTINUOUS button then the fog will exit
continuous output smoke status.
When the fog machine is ready to puff smoke, press the TIMER button, the fog machine will woke under time control, you can
also adjust the output volume of smoke by the volume wheel, and also can adjust output intervals by the interval knob, of which
the interval usually is 15seconds, and by repress this interval the fog machine will exist this interval control.

2. DMX MODE:

Please connect the fog machine with DMX cable, and please pay attention to choose correct polarity. Please push the DIP switch
to be off, then turn one power, the blue LED indicator in the back controller board flashes means fog machine has accepted
DMX signal. Please noted that this fog machine has only 2 DMX Channel, the first channel is to control the output smoke
volume, the second DMX channel is to control the working power of fan ;
3. Master-slave work mode:
Please connect the fog machines with DMX cable, and set one of them as the master machine, and other as slave machines.
Please push DIP 11 is ON of the master machine, and set the slave machines the DIP is ON, then all the slave machines can work
synchronously with the master machine.
4. Over-heat protection
When the fog machine is too hot, it will pause and start again when temperature drops.