troubLeshooting guide _________________________________________________________________________
Always follow the preparation procedure described in the operating instructions scrupulously. This will save you from most of the inconveniences.
If you encounter difficulties, here is a table that will help you understand why, and how to solve the problem.
Problem
The lamp indicating that the ice-tray is full is on
while the latter isn't full.
The lamp indicating that there isn't sufficient
water in the appliance is lighted but the tank
isn't empty (more than 1 cm to the bottom of
the tank).
No indicator lamp lights up when
the appliance is connected.
Both lamps indicating that the ice-tray is full
and that there isn't sufficient water in the
appliance flash at the same time.
Cause
The room temperature is too cold.
The sensor is no longer operating.
The conductivity of water is too low.
The sensor is no longer operating.
The appliance is not connected properly.
The motor has an operating problem.
The ice-cubes formed are too big. They are
stuck together and cannot fall into the ice-tray.
45
solution
Remove the ice-tray, and re-insert it when the
indicator lamp goes off.
Contact the After Sales Service.
Add a pinch of salt in the jug, stir well and
pour into the tank.
Contact the After Sales Service.
Check that the cord is correctly fixed and
that the outlet does not have any problem.
Otherwise, contact the after sales service.
Contact the After Sales Service.
Switch the appliance off and wait until the
ice-cubes melt, then restart the appliance
selecting a smaller size of ice cubes. If the
problem persists contact the After Sales
Service.