Herunterladen Inhalt Inhalt Diese Seite drucken

Hercules HT 102 Bedienungsanleitung Seite 39

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

3.4.5 CHECKING THE OIL LEVEL IN THE HYDRAULIC CIRCUIT (ONLY ON MACHINE UJ102 4X4)
The machine UJ102 4x4 is supplied with a bled hydraulic circuit and with an equalisation tank with the prescribed
amount of oil. The oil level in the tank may decline during transport. The equalisation tank is located under the hood
3.4.5
at the steering column
Check that the oil level is between the two marks on the equalisation tank, if necessary fill up with the necessary amount of the
prescribed oil. (
6.3.16).
Wipe clean the area around the tank opening and the tank opening itself. Also regularly clean the entire tank, because any dirt in
the oil reduces the lifespan of the oil filter and may possibly cause a malfunction.
3.4.6 BLEEDING AIR FROM THE HYDRAULIC CIRCUIT (ONLY ON MACHINE UJ102 4X4)
in" with a mild load for 1 to 2 hours. In the event that during the initial "run in" the character of the hydrophone sound changes, then
continuously, retighten the plug.
3.4.7 CHECKING THE TIGHTNESS OF THE HYDRAULIC CIRCUIT (ONLY ON MACHINE UJ102 4X4)
any leaks, inform your service centre.
39

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ht 122Ht 102 4wdHt 110Ht 110 4wd

Inhaltsverzeichnis