Alarm Output; External Signal (Contact) - Helios KWL EC 220 D Eco R Montage- Und Betriebsvorschrift

Vorschau ausblenden Andere Handbücher für KWL EC 220 D Eco R:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Außenluft
Fühler
NTC-Fühler
Fortluft
nluft
sw
Außenluft
Zuluft
NTC-Fühler Zuluft
Installation and Operating Instructions
Zuluft
Abluft
hler Abluft
ws
Abluft
EN
0-10 V
gelb
M1
Fortluft
weiß
Drehz.Rückm.
EC
Ventilator
blau
GND
gelb
0-10 V
M2
Zuluft
weiß
Drehz.Rückm.
EC
Ventilator
blau
GND
24 V
0-10 V
GND
X7.8
Ext.
Externes
al extern
Steuersignal
Ext.
X6.7
X10.14
STB
Rückmeldung
al extern
Sicherheits Temperatur Begrenzer
STB
X10.13
rt
Bypass
12V+/-
sw
ws
Bypass
Bypass
GND
X3 (außen)
001 17.12.10
Fortluft
Trafo
Sekundär
Fortluft
T5
Heizung
T5
Compact ceiling units KWL EC 220 D Eco
T6
T6
X5
X4 (innen)
T1 - Außenluft
Configuration DIBt: The supply air fan flow rate is reduced by 50 % and the pre-heater is activated. If the exhaust air
315mAT/250V~
T2 - Zuluft
temperature does not exceed the heat exchanger frost protection temperature within 5 min., the pre-heater will be
T3 - Abluft
T4 - Fortluft
deactivated and the supply air fan will be operated at the highest fan stage for 1 min. and then deactivated for safety
reasons. The extract air fan will remain active to heat the heat exchanger. If the exhaust air temperature exceeds the
heat exchanger frost protection temperature, the normal operating mode will be activated.

3 .1 .6 Alarm output

Function setting of various parameters (potential-free contact!)

3 .1 .7 External signal (contact)

Function setting of various parameters (potential-free contact!)
Allocation
"Dip switch", see wiring diagram SS-1003
DIP-Schalter
1.1
1.2
2.1 2.2
on
on
off
off
Funktion, siehe MBV
*Factory settings
Dip
No .
No .
switch
1
2
1
off
off
1
on
off
1
off
on
1
on
on
2
off
--
2
on
--
2
--
off
2
--
on
U3
L
X6.3
U3S
U2
L
Trafo
Trafo
L
S1
L
L
Relais 1
U1
Zul. br.
L
U1
For. br.
Relais 4
11
X7.4
12
X6.5
14
X2 (oben)
X1 (unten)
Allocation to
Description
function
If contact is open, the unit will switch to standby mode (stage 0), the protec-
tion functions (e.g. heat exchanger frost protection) will remain active. If the
contact is closed, the unit will switch to ventilation mode.
If a switch is connected, the unit will operate at the highest fan stage (Boost)
for 15 minutes with a closed contact (max. 2 sec.). If the contact is closed
for more than 2 sec., the unit will operate at the highest fan stage. If the con-
tact is open, the previously activated operating mode will be used.
External
If a switch is connected, the unit will operate at the highest fan stage (Boost)
contact
for 30 minutes with a closed contact (max. 2 sec.). If the contact is closed
for more than 2 sec., the unit will operate at the highest fan stage. If the con-
tact is open, the previously activated operating mode will be used.
If the contact is closed, the bypass will open. "External contact" will be sig-
nalled on the display. If the contact is open, the bypass will close again.
Unit operated according to passive house criteria.
Unit configu-
ration
Unit operated according to DIBt criteria.
Relay output when unit is on.
Error output
(composite
error)
Relay output in case of unit errors (defective fans, frost protection heat
exchanger, filter change etc.).
8
U3S
Vor - Heizung,
externe Komponente
N
N
T1, Zusatz-Trafo
N
S1
Haupt-
N
Versorgung
Platine
N
N
Zul. bl.
Versorgung
Ventilatoren
N
For. bl.
N
Alarm
14
X7.6