The pumps are designed for pumping clean water and chemically non-aggressive liquids. Any gua-
rantee is void in case of improper use. They are not suitable for pumping flammable liquids or for use
in places where there is danger of an explosion. The pumps are designed for home use in the house
and garden. The pumps are not designed for continuous operation or for professional work. Never run
more than 5 minutes against a closed valve pump. Save the pump against dry running (install dry run
protection).
Never start and stop the pump more than 20 times per hour. When the pump clocks, any
claim under warranty is void. Not suitable for use with solar photovoltaic panels. Submersi-
ble pumps may not be used in swimming pools.

4. OPERATION

The installation must be performed by a qualified professional.
Please, check each time before using, the electrical connections and the cables are not
damaged. Check before the installation whether the electrical connections are earthed
according to the statutory regulations and are installed. The pump is to be secured
through a RCD circuit breaker with release current of 30 mA.
Also, it is NOT recommended to perform, for example, a cable extension. It is not certain
whether this modification is technically correct, so this warranty is void. It must be en-
sured that the pump is sufficiently cooled during prolonged operation.
It is not recommended to perform even cable extensions or other technical modifica-
tions. A transfer of mechanical loads or vibrations from the pump or must be eliminated
through appropriate measures (rubber buffers, braided hoses, line fixation, etc.).
All cables to and from the pump must be sealed. Check valve and water pipes for leaks
at least by means of pressure testing for 24h.

5. INSTALLATION

The Brunnen-Star-Automatic 560-20 and 720-20 pumps with / without sand prefilter
are designed for use in deep well drilling.
The Regen-Star-Automatic 600-10 / 750-10 pumps are designed for use in rainwater cisterns
and other tanks.
Before first use, attach a sufficiently long and strong rope to the handle.
The pump is hooked into the water tank with this rope.
Note:
The condition of the rope should be checked regularly as it can age and
possibly tear over time.
l Assembly of the pressure line:
We recommend using the pressure hose from our product range (Art.No.A3654)
with appropriate pressure resistance and matching hose nozzles. Mount the pressure line on
the pressure connection. All threaded connections must be sealed with an appropriate
sealing tape (for example Teflon®-Band)
l Assembly of the suction line (for Regen-Star-Automatic 600-10 / 750-10 only):
As a protective measure against the suction of bottom sediment, we recommend the
installation of floating Inlet (Art.No. A8144 ).
The floating inlet is to be fixed with the rope in such a way that it will be hanging
in a suitable height without touching the ground. We recommend a ground clearance of
about 15-20 cm. Make sure, the pump is in stable fixed position.
For this purpose we recommend the pump feet (Art.No.A 927) .
IMPORTANT!