15

Technical data

Table 4
General data
Order number
Input
Input voltage
Input current
Output
Intermediate circuit output voltage
Max. intermediate circuit output voltage
Nominal power
Peak power
Internal supply voltage
VEE
VCC
VDD
24 V
external supply voltage (V
ext
Interference suppression
Interference immunity
Permissible ambient temperature
Admissible relative humidity during operation
Max. permissible altitude for use
Operation at altitudes greater than 1000 m
above mean sea level
Admissible storage temperature
Admissible relative storage humidity
Protection class
Protection type
Dimensions (W x H x D)
Weight
Switching cycles of emergency OFF circuit
VM350
0 608 750 110
200 - 265 V, single or three-phase, 50 - 60 Hz
Depending on the voltage and type of connection,
e.g. 3-phase 230 V: 3 x 7.5 A
200 V
DC
420 V
DC Max
3000 VA (at 230 V) 3-phase
1500 VA (at 230 V) single-phase
1000 VA (at 110 V) single-phase
10000 VA (at 230 V) for 5 s
24 V
5.1 V
–24 V
at XDN2)
24 V
EE
EN 55011 class A
DIN EN 61000-4 part 2 to part 5 severity class 4
0 to 60 °C with fan
20 - 90 %, non-condensing
2000 m above sea level (for altitudes more than
2000 m above sea level, we recommend the use of
an isolating transformer)
At more than 1000 m above mean sea level, a reduc-
tion in the nominal power of approx. 1% per 100 m
of altitude may occur due to the reduced air pres-
sure.
–20 °C to 70 °C
20 - 95 %
Protection class I
IP20 (protection against accidental contacts) when
installed
53 mm x 271 mm x 285 mm
2.8 kg
approx. 1 million
Bosch Rexroth AG
nom
3 x 30 A
peak
... 325 V
... 370 V
DCnom
DC
10 A
(± 8%)
7 A
(± 3%)
0.8 A
(+20% / –10%)
1 A
(± 8%)
37/112
for 5 s