Industrieprotokolle
16.3 EtherNet/IP
Tab. 74:
Id
Attribute
0x6
Ethernet Interface
4
Index
0x6
Port Control
5
0x6
Interface Utilization
6
0x6
Interface Utilization
7
Alarm Upper
Threshold
0x6
Interface Utilization
8
Alarm Lower
Threshold
0x6
Broadcast limit
9
0x6
Ethernet Interface
A
Description
444
Hirschmann-Erweiterungen des Ethernet-Link-Objekts
Access
Rule
Get
Get/Set DWORD
Get
Get/Set USINT
Get/Set USINT
Get/Set USINT
Get/Set STRING
Data type
Description
USINT
Interface/Port Index (ifIndex out of
MIBII)
0: Link state
1: Link admin state
8: Access violation alarm (read-only)
9: Utilization alarm (read-only)
USINT
The existing Counter out of the private
MIB hm2IDiagfaceUtilization is used.
Utilization in percentage (Unit
1%=100, %/100). RX Interface
Utilization.
Within this parameter the variable
hm2DiagIfaceUtilizationAlarmUpperT
hreshold can be accessed. Utilization
in percentage (Unit 1%=100).
RX Interface Utilization Upper Limit.
Within this parameter the variable
hm2DiagIfaceUtilizationAlarmLowerT
hreshold can be accessed. Utilization
in percentage (Unit 1%=100). RX
Interface Utilization Lower Limit.
Broadcast limiter Service
(Egress BC-Frames limitation,
0=disabled), Frames/second
Interface/Port Description
(from MIB II ifDescr), for example
"Unit: 1 Slot: 2 Port: 1 - 10/100 Mbit
TX" or
"unavailable", max. 64 Bytes.
(0=link down, 1=link up)
(0=disabled, 1=enabled)
UM Config MSP30