Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Connection - Electrolux RZB2110AAK Benutzerinformation

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Mains supply cable length.
Cable is placed in the right
corner of the back side
Mounting screws

2.2 Electrical connection

WARNING!
Risk of fire and electric shock.
• All electrical connections should be made
by a qualified electrician.
• The appliance must be earthed.
• Make sure that the parameters on the
rating plate are compatible with the
electrical ratings of the mains power
supply.
• Always use a correctly installed
shockproof socket.
• Do not use multi-plug adapters and
extension cables.
• Make sure not to cause damage to the
mains plug and to the mains cable.
Should the mains cable need to be
replaced, this must be carried out by our
Authorised Service Centre.
• Do not let mains cables touch or come
near the appliance door or the niche
below the appliance, especially when it
operates or the door is hot.
• The shock protection of live and insulated
parts must be fastened in such a way that
it cannot be removed without tools.
• Connect the mains plug to the mains
socket only at the end of the installation.
Make sure that there is access to the
mains plug after the installation.
• If the mains socket is loose, do not
connect the mains plug.
• Do not pull the mains cable to disconnect
the appliance. Always pull the mains plug.
• Use only correct isolation devices: line
protecting cut-outs, fuses (screw type
fuses removed from the holder), earth
leakage trips and contactors.
• The electrical installation must have an
isolation device which lets you disconnect
the appliance from the mains at all poles.
The isolation device must have a contact
opening width of minimum 3 mm.
• This appliance is supplied only with a
main cable.
26
ENGLISH
1100 mm
H07 RN-F, H05 RN-F, H05 RRF, H05 VV-F, H05
2x25 mm
V2V2-F (T90), H05 BB-F
For the section of the cable refer to the total
power on the rating plate. You can also refer
to the table:
Total power (W)
maximum 1380
maximum 2300
maximum 3680
The earth cord (green / yellow cable) must be
2 cm longer than phase and neutral cables
(blue and brown cables).
2.3 Use
• This appliance is for household (indoors)
• Do not change the specification of this
• Make sure that the ventilation openings
• Do not let the appliance stay unattended
• Deactivate the appliance after each use.
• Be careful when you open the appliance
• Do not operate the appliance with wet
• Do not apply pressure on the open door.
• Do not use the appliance as a work
• Open the appliance door carefully. The
• Do not let sparks or open flames to come
Cable types applicable for installation or
replacement for Europe:
WARNING!
Risk of injury, burns and electric
shock or explosion.
use only.
appliance.
are not blocked.
during operation.
door while the appliance is in operation.
Hot air can release.
hands or when it has contact with water.
surface or as a storage surface.
use of ingredients with alcohol can cause
a mixture of alcohol and air.
in contact with the appliance when you
open the door.
Section of the cable
(mm²)
3 x 0.75
3 x 1
3 x 1.5

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Rzb2110aax

Inhaltsverzeichnis