7. Configuration
OUT1 hysteresis with
HYh
Input of the hysteresis of control output 1 with
Only available with
Setting range: 0.1 ... 100.0 °C (°F)
GB
OUT2 control mode
cAcF
Selection of the control mode for control output 2
Not available if the option 2, control output [DT2] is not present, or if
mode is set for control output 2.
Selection:
OUT2 maximum output power
oLHb
Input of the maximum output power for control output 2
Not available if the option 2, control output [DT2] is not present, or if
mode is set for control output 2.
Setting range: OUT2 minimum output power to 100 %
OUT2 minimum output power
oLLb
Input of the minimum output power for Control Output 2
Not available if the option 2, control output [DT2] is not present, or if
mode is set for control output 2.
Setting range: 0 % to OUT2 maximum output power
Overlap band/deadband
db
Setting of the overlap band/deadband for control outputs 1 and 2.
+ Setting value: deadband
– Setting value: overlap band
Not available with
not present.
Setting range: -100.0 ... +100.0 °C (°F)
OUT2 hysteresis with
HYhb
Input of the hysteresis for control output 2 with
Only available if the option 2, control output [DT2] is present and if
mode is set.
Setting range: 0.1 ... 100.0 °C (°F)
Alarm type alarm 1 (A1)
AL1F
Setting of the alarm type for alarm 1 (A1)
Selection:
no alarm
High alarm
Low alarm
High/Low alarm
Range alarm
Alarm type alarm 2 (A2)
AL2F
Setting of the alarm type for alarm 2 (A2)
Only available when the options [2AS] or [2AL] are present.
The alarm types are identical with those of alarm 1 (A1).
Switch behaviour, alarm 1 (A1)
A1LA
Selection of the switch behaviour for alarm output 1 (A1)
(Relay activated/deactivated on alarm)
Not available when "no alarm" is selected as alarm type for alarm 1 (A1).
Selection:
28
/
control mode
ON
OFF
/
control mode.
ON
OFF
with current/voltage signal input, 1 ... 1,000
Selection: (air cooling, linear characteristic)
AIr
(Oil cooling, 1.5-times linear characteristic)
oIL
(Water cooling, 2-times linear characteristic)
8AF
/
control mode or if the option 2, control output [DT2] is
ON
OFF
with current/voltage signal input: -1,000 ... 1,000
/
control mode
ON
OFF
with current/voltage signal input: 1 ... 1,000
----
H
L
HL
8Id
(activated)
noAL
(deactivated)
rE8h
/
control mode
ON
OFF
/
control mode
ON
OFF
Process high alarm
Process low alarm
High alarm with standby
Low alarm with standby
High/Low alarm with standby HL8
WIKA operating instructions model CS4S
1.0 °C
Air cooling
/
control
ON
OFF
100 %
/
control
ON
OFF
0 %
/
control
ON
OFF
0 °C
1.0 °C
/
control
ON
OFF
no alarm
Ah
rAh
H 8
L 8
no alarm
activated