- 'HygieSteam': the machine thoroughly cleans the internal milk system with steam. Make sure that
the HygieSteam container is correctly assembled (Fig. 44) and attached to the machine (Fig. 45).
Place the milk tube in the milk tube holder (Fig. 46) and follow the instructions on the screen.
- 'Deep Milk Clean': Perform the 'Deep Milk Clean' procedure with the Philips milk circuit cleaner for a
thorough cleaning of the internal milk system.
Cleaning the internal cappuccinatore under the tap
1 Open the door of the internal cappuccinatore (Fig. 47).
2 Remove the internal cappuccinatore by pulling it down (Fig. 48).
3 Disassemble the internal cappuccinatore by pulling the bottom part off the top part (Fig. 49).
4 Disassemble all parts (Fig. 50) and clean them under the tap.
5 Reassemble the internal cappuccinatore.
6 To place back the internal cappuccinatore, put it in upright position and make sure the holes are
aligned with the two tubes on the machine. Then move the internal cappuccinatore upwards until it
locks into place (Fig. 13).
7 Close the door.
Visit www.saeco.com/care for detailed video instructions.
Descaling procedure
Please use Philips descaler only. Under no circumstances should you use a descaler based on sulfuric
acid, hydrochloric acid, sulfamic or acetic acid (vinegar) as this may damage the water circuit in your
machine and will not dissolve the limescale properly. Not using the Philips descaler will void your
warranty. Failure to descale the appliance will also void your warranty. You can buy Philips descaler in
the online shop at www.saeco.com/care.
1 When the machine asks you to descale it, press the start/stop
without being prompted by the machine, tap the Clean
2 Remove the drip tray, the coffee grounds container and the HygieSteam container (Fig. 35), empty
them and put them back into place.
3 Remove the water tank and empty it. Then remove the AquaClean filter.
4 Pour the whole bottle of Philips descaler into the water tank and then fill it with water up to the
CALC CLEAN level (Fig. 51). Then place it back into the machine.
5 Place a large container (1.5 l) under the coffee dispensing spout.
6 Make sure that the HygieSteam container is correctly assembled (Fig. 44) and attached to the
machine (Fig. 45). Place the milk tube in the milk tube holder (Fig. 46).
7 Follow the instructions on the screen to start the descaling procedure. The descaling procedure
lasts approx. 30 minutes and consists of a descaling cycle and a rinsing cycle.
8 Once the descaling cycle is finished, you need to rinse the water tank and water circuit. Follow the
instructions on the screen.
9 Place a new AquaClean filter in the water tank and activate it (see 'Activating the AquaClean water
filter (5 min.)').
Tip: Using the AquaClean filter reduces the need for descaling!

What to do if the descaling procedure is interrupted

You can exit the descaling procedure by pressing the on/off button on the control panel. If the
descaling procedure is interrupted before it is completely finished, do the following:
1 Empty and rinse the water tank thoroughly.
button to start. To start descaling
icon and select 'Descale'.