Herunterladen Inhalt Inhalt Diese Seite drucken

Candy PVS 640 Bedienungsanleitung Seite 11

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 16
• Models PVD
The hob is fitted with a power supply cord which allows it to be
connected only to a power supply of 220-240 V between phases
or between phase and neutral.
• Connect to a socket, to choose the correct fuse, you must
refer on the table.
It is however possible to connect the hob to :
. Three phase
. Three phase
To proceed to the new connection, you must adhere the
following instructions.
• Before making the connection, make sure that the installation
is protected by a suitable fuse, see table, and that it is fitted with
wires of a large enough section to supply the appliance normally.
• Turn over the hob, glass side against the work top, taking care
to protect the glass.
• Open the cover in the following sequence:
1
2
• unscrew the cable clamp "1",
• find the two tabs located on the sides,
• put the blade of a flat screw-driver in front of each tab "2" e "3",
push in and press,
• remove the cover.
To release the power supplying cord.
• remove the screws retaining the terminal block which contains
the shunt bars and the conductors of the supply cord,
• Pull out the supply cord.
• Operations to be carried out to make a new connection :
- Choose the power supply cable in accordance with the
recommendations in the table.
- Pass the power supply cable into the clamp.
SHUNT
Note: make sure the terminal board screws are tight.
220-240 V3~
380-415 V2N~
3
- Strip the end of each conductor of
the supply cord on a 10 mm length,
by taking in account the requested
length of the cord for the connection
to the terminal block.
- According to the installation
and with the help of shunt bars which
you should have recovered in the
first operation, fix the conductor as
shown on the chart.
- Fix the cover.
- Screw the cable clamp.
Connection to the terminals on the terminal block
Monophase 220-240 V~
Three phases 220-240 V3~
Ph = Phase
VITROCERAMIC HOB WITHOUT CONTROL
KNOBS "PVS"
Connection to the electrical circuit, on the oven or glass ceramic
hob, should be made via the oven. For this reason, it is important
that the instructions given in the oven instructions booklet are
followed carefully.
The ceramic hob without controls "PVS", has been developed to
be used only in conjunction with specific separate control units or
built in ovens with integral hob controls.
A detailed table (supplied with ovens with integral hob control or
with independent control units) shows clearly how the hobs are
to be connected to the specified units.
Under no circumstances must the hob be connected with any
other control or oven not specified in the list.
To proceed with the connection, it is necessary to joint male
connectors
1
and
2
3
of the oven or of the control panel.
INSTALLATION WITH OVEN
This connection can be made before or after the oven is
10 GB
Two phases 220-240 V2~
Three phases 380-415 V2N~
N = Neutral
T = Earth
of the hob with the "female" connectors
HOB
OVEN
550x10
Built-in oven "apertures" : Refer to
the instruction booklet concerned.
screwed into place.