Connection to the mains
The device uses an auto-range power supply that accepts input voltages between 100 und 240 volts.
1
Connect the device via the enclosed mains cable to a grounded mains socket. Thus the unit is switched
on.
2
To switch off the unit, disconnect the power plug.
3
Do not connect the unit to the mains voltage via a dimmer. For a more convenient operation, use a mains
outlet which is switchable.
Stand-alone operation
In stand-alone mode, the LED TMH-W63 can be used without controller. Disconnect the LED TMH-W63 from
the controller and call up the internal program. Please refer to the instructions under Menu structure.
Master/Slave operation
The master/slave operation enables that several devices can be synchronized and controlled by one master
device.
On the rear panel of the device you can find an XLR-jack (DMX Out) and an XLR-plug (DMX In), which can
be used for connecting several devices.
Choose the device which is to control the effects. This device then works as master device and controls all
other slave-devices, which are to be connected to the master device via a DMX cable. Connect the DMX
OUT-jack with the DMX IN-plug of the next device.
Set the master device to the desired master mode "Auto" or "Soun". Set the desired slave mode "SL 1" or
"SL 2" on all slave devices. Please refer to the instructions under Menu structure.
OPERATION
After connecting the device to the mains it is ready for operation. The display indicates the last operating
mode. The operating modes can be selected by means of the display and the control buttons. All settings
remain stored even if the device is disconnected from the mains. The device can be operated in stand-alone
mode via the control board or in DMX-controlled mode via any commercial DMX controller.
22/28
00127064, Version 1.0