Make sure that a module is inserted in the device.
Make sure that the air inlet and nozzle outlet are not covered so that a sufficient flow of
ambient air can be drawn in by the unit.
Hold the unit only in the area of the button (picture 4), not in the area in front of it
(picture 3).
If the unit is to be mounted stationary, please observe the instructions below regarding
electrically conductive objects (picture 5 to 8).
Ensure that the ventilation / extraction of the working area is sufficient.
Press the Start/Stop button to generate plasma
The device stops plasma activation after 5 minutes at the latest and goes into standby
mode (in the case of special modules, plasma activation can stop after a shorter period of
time).
You can return to the active mode by simply pressing the Start/Stop button and restart the
activation by pressing the Start/Stop button again.
Do not reach into the work area during plasma generation. This can disturb the plasma
discharge and can also cause skin irritation or be perceived as slightly painful.
Attention - Damage to device!
The device can be damaged if it is operated without air supply.
This would interrupt the supply of the cooling medium required during operation.
Never cover the air inlet and/or the nozzle outlet during operation.
The device can be damaged if electrically conductive objects are closer than 60 mm to the
front third of the device during operation.
Exception: Substrates in front of the module when using modules designed for this
purpose, e.g. the Module „Nearfield".