4 Operation
Item
k Additional zone
k1 Installed room thermostat type:
Unit operation is decided by the external room
thermostat (wired or wireless).
No room thermostat installed or set. Unit operation
is decided based on the leaving water temperature
regardless of the actual room temperature and/or
heating demand of the room.
k2 Installed heat emitter type:
Underfloor heating
Fancoil unit
Radiator
45
k3
Leaving water temperature setpoint
l
Malfunction
A malfunction occurred.
See
"7.1 To display the help text in case of a
malfunction" [ 4  19] for more information.
(a)
If the corresponding operation (for example: space heating) is not
active, the circle is greyed out.
4.3.2

Main menu screen

Starting from the home screen, press (
left dial to open the main menu screen. From the main menu, you
can access the different setpoint screens and submenus.
2
Malfunctioning
Room
Main zone
Additional zone
Space heating/cooling
a
Selected submenu
Possible actions on this screen
Go through the list.
Enter the submenu.
Enable/disable breadcrumbs.
Submenu
[0]
Restriction: Only displayed if a
or
malfunction occurs.
Malfunctioning
See
case of a
information.
[1]
Restriction: Only displayed if a
Room
dedicated Human Comfort Interface
(BRC1HHDA used as room
thermostat) is controlling the indoor
unit.
Set the room temperature.
[2]
Shows the applicable symbol for your
Main zone
main zone emitter type.
Set the leaving water temperature for
the main zone.
[3]
Additional zone Restriction: Only displayed if there
are two leaving water temperature
zones. Shows the applicable symbol
for your additional zone emitter type.
Set the leaving water temperature for
the additional zone (if present).
Operation manual
10
Description
(a)
) or turn (
) the
a
Description
"7.1 To display the help text in
malfunction" [ 4  19] for more
Submenu
[4]
Shows the applicable symbol of your
Space heating/
unit.
cooling
Put the unit in heating mode or cooling
mode. You cannot change the mode
on heating only models.
[5]
Set the domestic hot water tank
Tank
temperature.
[7]
Gives access to user settings such as
User settings
holiday mode and quiet mode.
[8]
Displays data and information about
Information
the indoor unit.
[9]
Restriction: Only for the installer.
Installer
settings
Gives access to advanced settings.
[A]
Restriction: Only for the installer.
Commissioning
Perform tests and maintenance.
[B]
Change the active user profile.
User profile
[C]
Turn heating/cooling functionality and
Operation
domestic hot water preparation on or
off.
[D]
Restriction: Only displayed if a
Wireless
wireless LAN (WLAN) is installed.
gateway
Contains settings needed when
configuring the Daikin Residential
Controller app.
4.3.3

Setpoint screen

The setpoint screen is displayed for screens describing system
components that need a setpoint value.
Examples
[1] Room temperature screen
1
+
21
°C
Room
[3] Additional zone screen
3
+
45
°C
Additional zone
Explanation
d
c
+
a2
b2
e
d
d
e
a1
b1
Possible actions on this screen
Go through the list of the submenu.
Go to the submenu.
Adjust and automatically apply the desired
temperature.
ETVH/X16S18+23DA6V+9W(G) + ETBH/X16DF6V+9W
Description
[2] Main zone screen
2
+
35
°C
Main zone
[5] Tank temperature screen
5
+
50
°C
Tank
Daikin Altherma 3 H HT F+W