4 Operation
Tank heating operation
NOTICE
Disinfection mode. Even if you turn OFF tank heating
operation ([C.3]: Operation > Tank), disinfection mode will
remain active. However, if you turn it OFF while
disinfection is running, an AH error occurs.
1 Go to [C.3]: Operation > Tank.
C.3
Operation
Space heating/cooling
On
Tank
Off
2 Set operation to On or Off.
4.5

Reading out information

To read out information

1 Go to [8]: Information.

Possible read-out information

In menu...
[8.1] Energy data
[8.2] Malfunction history
[8.3] Dealer information
[8.4] Sensors
[8.5] Actuators
[8.6] Operation modes
[8.7] About
[8.8] Connection status
[8.9] Running hours
4.6

Space heating/cooling control

4.6.1

Setting the space operation mode

About space operation modes
Your unit can be a heating or a heating/cooling model:
▪ If your unit is a heating model, it can heat up a space.
▪ If your unit is a heating/cooling model, it can both heat up and cool
down a space. You have to tell the system which operation mode
to use.
To tell the system which space operation to use, you can:
You can...
Check which space operation mode is
currently used.
Set the space operation mode permanently. Main menu
Restrict automatic changeover according to
a monthly schedule.
Operation manual
12
You can read out...
Produced energy, consumed
electricity, and consumed gas
Malfunction history
Contact/helpdesk number
Room, tank or domestic hot
water, outside, and leaving water
temperature (if applicable)
Status/mode of each actuator
Example: Domestic hot water
pump ON/OFF
Current operation mode
Example: Defrost/oil return
mode
Version information about the
system
Information about the connection
status of the unit, the room
thermostat and the LAN adapter.
Running hours of specific system
components
Location
Home screen
To set the space operation mode
1 Go to [4.1]: Space heating/cooling > Operation
mode
2 Select one of the following options:
▪ Heating: Only heating mode
▪ Cooling: Only cooling mode
▪ Automatic:
The
operation
automatically between heating and cooling based
on the outdoor temperature. Restricted per month
according to the Operation
[4.2].
To restrict automatic changeover according to a schedule
Conditions: You set the space operation mode to Automatic.
1 Go to [4.2]: Space heating/cooling > Operation
mode schedule.
2 Select a month.
3 For each month, select an option:
▪ Reversible: Not restricted
▪ Heating only: Restricted
▪ Cooling only: Restricted
4 Confirm the changes.
4.6.2

To change the desired room temperature

During room temperature control, you can use the room temperature
setpoint screen to read out and adjust the desired room temperature.
1 Go to [1]: Room.
1
Room
2 Adjust the desired room temperature.
a
b
1
21
°C
Room
a Actual room temperature
b Desired room temperature
If scheduling is on after changing the desired room temperature
▪ The temperature will stay the same as long as there is no
scheduled action.
▪ The desired room temperature will return to its scheduled value
whenever a scheduled action occurs.
You can avoid scheduled behaviour by (temporarily) turning off
scheduling.
To turn off room temperature scheduling
1 Go to [1.1]: Room > Schedule.
2 Select No.