Problem
wings at crimped ca-
ble lug / connector
the connection be-
tween cable lug / con-
ductor is not okay; the
conductor is not fixed
after crimping
profile die is fixed
profile dies can only
be turned around diffi-
cultly, heavily
tool has no prestress-
ing at closed status
32
Cause
• a too small cross section is
adjusted at the crimping
tool
• usage of wrong, unquali-
fied cable lugs / connec-
tors for the tool
• other causes
• a too big cross section is
adjusted at crimping tool
• usage of wrong, unquali-
fied cable lugs / connec-
tors
• other causes
• locking bolt has snapped
in
• tool is soiled
• tool is insufficient oiled
• tool is worn
Solution
• adjust the right cross
section
• change the cable lug /
connector
• change crimping tool
• inquire manufacturer,
crimping tool must be
checked by manufac-
turer
• adjust the right cross
section
• change the cable lug /
connector
• change crimping tool
• inquire manufacturer,
crimping tool must be
checked by manufac-
turer
• press down locking bolt
• clean the tool
• oil the bolts and screws
• is the problem not solved,
inquire manufacturer;
crimping tool must be
checked by manufacturer
• crimping tool must be
checked by manufac-
turer
1548670000/00/06.14