Drinking water withdrawal
Please open the withdrawal tap.
If the Verdanium Home is in standby mode for more than 15 minutes, it will produce drinking water only
after approx. 15 - 30 seconds. During this time, the filter is rinsed and prepares itself for ultra-pure water
production.
The following messages appear on its display:
PERMEATE PRODUCTION
Automatic
Membrane rinse
ESC ←
080%
After rinsing, the Verdanium Home automatically changes to ulta-pure water production. The following
messages appear on its display:
PERMEATE PRODUCTION
device in operation
ESC ←
To stop ultra-pure water production, close the withdrawal tap.
After the water production finishes, the system prepares for standby mode. The following messages ap-
pear on the display:
PERMEATE PRODUCTION
Automatic
rinsing
ESC ←
050%
The Verdanium Home is now in standby mode.
48
Instruction Manual – Verdanium Home – Ver. 2.1.1 – 12.2020
PERMEATE PRODUCTION
Permeate rinse
ESC ←
030%
PERMEATE PRODUCTION
device in operation
ESC ←
As soon as the message "Attention! Maintenance required! Please replace all filter units!" appears on the
display, the pre- and post-filters need to be changed.
The message „Attention maintenance required! Please replace all filter units!" is only
displayed during the annual filter change.
The semi-annual pre-filter change must be organised by the user.
PERMEATE PRODUCTION
device in operation
Stop the permeate production mode with the
ESC ←
Preparation for
Select in the menu the operating mode "Maintenance Prepara-
Maintenance
tion". Confirm with the
Follow the instructions on the display.
ESC ←
→ OK
- Close corner valve
Disconnect the water supply to your device and open the with-
drawal tap. Confirm with the
- Open withdrawal tap
After you open the withdrawal tap, the pressure in the supply
tube will be reduced. Please wait until the next instruction is
→ OK
shown on the display.
- Disconnect tube
Now disconnect the inlet tube from the angle valve and press
the
OK-Button
→ OK
Reset after filter
change:
To reset the filter change interval, you must select in the ope-
Hold keys
rating mode menu the buttons (B) and (–) and hold them for at
least 5 seconds.
"B" and "-" 5s
Instruction Manual – Verdanium Home – Ver. 2.1.1 – 12.2020
Filter change
ESC-Key.
OK-Button.
OK-Button.
to confirm.
49