Herunterladen Inhalt Inhalt Diese Seite drucken

Installation Location - STIEBEL ELTRON WSN 10 Bedienung Und Installation

Sensor-armatur für offene (drucklose) warmwassergeräte
Vorschau ausblenden Andere Handbücher für WSN 10:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

INsTALLATIoN
Preparation
9.
Preparation
9.1

Installation location

Installation example:
10. Installation
Damage to the appliance and environmental pollution
!
Refer to the operating and installation instructions for the
DHW appliance. Only use aerators that are permissible
for the DHW appliance.
Note
Make sure that the hoses are not kinked during installa-
tion and that the electrical connection is not damaged.
20  |  WSN 10 | WSN 20 
f Install the strainer and gaskets (the tee is not included in the
f
standard delivery). Strainers are self-sealing.
Only WSN 10:
f Connect the sensor tap to the power supply unit. Plug in the
f
power supply unit.
11. Commissioning
f Flush the pipeline.
f
f Open the angle valve. Adjust the water to the required vol-
f
ume at the angle valve.
A
C
E
f Commission the sensor tap:
f
A Remove the label.
B Wave your hand within range of the sensor.
C Move your hand out of range of the sensor.
D Water runs for approx. 4 seconds.
E Wait another 10 seconds. The sensor tap is now ready for
operation.
13
B
1x 2 Sec.
D
10 sec.
www.stiebel-eltron.com
4 sec.