Herunterladen Diese Seite drucken

Indel B SLEEPING WELL OBLO Montageanleitung Seite 3

Vorschau ausblenden Andere Handbücher für SLEEPING WELL OBLO:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

SLEEPING WELL OBLò
9.
Insert the electrical wires that protrude from the air diffuser between the roof and the inner lining, directing them towards
the front of the vehicle (see fig.4).
10.
Insert the M8x150 screws with washers and nuts onto the brackets, positioning the latter by inserting the end between the
lining and the roof.
Tighten the screws into the threaded cylindrical holes in the roof unit, then tighten the nuts beneath against the brackets
(see fig.5a).
11.
The brackets are asymmetric. The longer part has to be mounted to the front part of the vehicle (pic.4).
12.
Working from the outside, carefully apply sealant above the end of the 2 rear screws which you have just tightened into the
threaded holes, as shown in fig.6.
13.
In presence of sloping roof, adjust the 4 lateral screws on the compressor (2 M8 and 2 M6) and, irrespective of the
inclination of the roof, keep the compressor resting base in the horizontal position (see fig.7). When the operation has
been completed, tighten the 4 screws.
14.
Then fasten the frame in place using T.C.E.I. screws ( ).
15.
Direct the 2 electrical wires towards the dashboard for connection to the fittings on the vehicle's main distribution frame
(red wire +24V, – black wire earth).
16.
In the case of direct connection to the battery, use at least a 30 Amp fuse.
17.
Check the functioning of the group (voir le manuel de maintenance et utilisation)
18.
After completing the assembly, refit the outer cover (see fig.9-10).