Dishwasher must be level for proper dish rack operation and wash performance.
1
Place a spirit level on door and rack track inside the tub as shown to check that the dishwasher
is level.
2
level the dishwasher by adjusting the three levelling legs individually.
3
When level the dishwasher, please pay attention not to let the dishwasher tip over.
Figure 8
Illustration of feet adjustment
NOTE:
The maximum adjustment height
of the feet is 50 mm.
About Power Connection
WARNING!
For personal safety:
Do not use an extension cord or an adapter plug with this appliance.
Do not, under any circumstances, cut or remove the earthing
Connection from the power cord.

Electrical Requirements

Please look at the rating label to know the rating voltage and connect the dishwasher to the appropriate power supply. Use the
required fuse 10 amp, time delay fuse or circuit breaker recommended and provide separate circuit serving only this appliance.
Insure proper ground
exists before use
How to Connect the safety supply hose
The appliance must be connected to the water mains using new hose-sets.
The old hose-sets should not be reused.
Water pressure must be between 0,04 MPa and 1 MPa. If the pressure is below the minimum
consult our Service Department for advice.
1. Pull The safety supply hoses completely out from storage compartment located at rear of
dishwasher.
2. Tighter the screws of the safety supply hose to the faucet with thread 3/4inch.
3. Turn water fully on before starting the dishwasher.
ABOUT THE SAFETY SUPPLY HOSE.
The safety supply hose consists of the double walls. The hose's system guarantees its intervention by blocking the flow of
water in case of the supply hose breaking and when the air space between the supply hose itself and the outer corrugated
hose is full of water.
Check level Front
to Back

Electrical Connection

Ensure the voltage and frequency of the power being corresponds to those on the rating
plate. Only insert the plug into an electrical socket which is earthed properly. If the electrical
socket to which the appliance must be connected is not appropriate for the plug, replace the
socket, rather than using a adaptors or the like as
they could cause overheating and burns.