4.2 Floor
Foundations
Ensure that the floor is strong enough for the fireplace.
See «2.0 Technical data» for weights.
Wooden floor protection
Requirements for the floor plate:
The floor plate must be in accordance with national laws
and regulations. (See Buildings Regulations.)
Requirement for protecting combustible
flooring in front of fireplace
The front plate must be in accordance with national laws
and regulations.
4.3 Walls
Distance to walls made of combustible
material
You may use the fireplace with an uninsulated flue pipe
provided the distances to walls made of combustible
materials are as shown in fig. 1.
Distance to walls protected by a firewall -
see fig. 1
Firewall requirement
The firewall must be at least 100 mm thick and be made
of brick, concrete-stone or light concrete. Other materials
and constructions with satisfactory documentation may
also be used, e.g. Jøtul Firepanel.
4.4 Ceiling
There must be a minimum distance of 100 mm to a
combustible roof above the fireplace.
4.5 Chimneys and flue pipes
• The fireplace can be connected to a chimney and flue
pipe approved for solid fuel fired fireplaces with flue
gas temperatures specified in «2.0 Technical data».
• The chimney's cross-section must be at least as big as
the flue pipe's cross-section. See «2.0 Technical data»
when calculating the correct chimney cross-section.
• Several fireplaces can be connected to the same
chimney if the chimney's cross-section is sufficient.
• Connection to the chimney must be carried out in
accordance with the installation instructions from the
supplier of the chimney.
• Before making a hole in the chimney the fireplace
should be test-mounted in order to correctly mark the
position of the fireplace and the hole in the chimney.
See fig. 1 for minimum dimensions.
Downloaded from
www.Manualslib.com
manuals search engine
• Ensure that the flue pipe is inclined all the way up to
the chimney.
• Use a flue pipe bend with a sweeping hatch that allows
it to be swept.
Be aware of the fact that connections must have a
certain flexibility in order to prevent movement in the
installation leading to cracks. N.B. A correct and sealed
connection is very important for the proper functioning
of the product.
The chimney draught should never exceed 2.5 mm H
Pa) when the fireplace is in use.
If the draught is too strong you can install and operate a
flue damper to control the draught.
In case of chimney fire
• Close all hatches and vents.
• Keep the firebox door closed.
• Check the loft and cellar for smoke.
• Call the fire service.
• Before use after a fire an expert must check the fireplace
in order to ensure that it is fully functional.
4.6 Control functions (fig. 2A and 2B)
When the product is set up, always check the control
functions. These shall move easily and function
satisfactorily.
Jøtul F 100 is equipped with the following controls:
Air wash vent,
fig. 2A.
fig. 2B
Ignition vent,
To the left:
Closed
To the right:
Open
ENGlish
O (25
2
17