Herunterladen Inhalt Inhalt Diese Seite drucken

Performance; Performance History - Elcon nect next BIG 10 Kurzbedienungsanleitung

Vorschau ausblenden Andere Handbücher für nect next BIG 10:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Data rate
The following data rates (in kbps) depending on the configuration of the COT side can be
achieved with the BIG 10:
Annex
Annex A/B
Annex AF/BG
Loop Attenuation (dB)
Measured loop attenuation in dB; longer loop length results in high loop attenuation.
SNR (dB)
The SNR ("signal noise ratio") is an index of the line quality. The larger the SNR the better is
the line quality. The SNR ranges from -10 dB to 21 dB.

3.4.3 Performance

This view shows actual performance values of all lines.
Time Stamp
Shows the time after activation of the NT function or the elapsed time (24h format) after acti-
vation of the SHDSL line.
TMP (total measurement period)
Full duration (time interval) of counting performance data; will be reset after 15 minutes =
900 seconds
ES (errored seconds)
number of seconds with errors
SES (severe errored seconds)
number of seconds with major alarms
CRC6 (cyclic redundancy check)
number of CRC6 errors
LOSW (los of sync word)
number of LOSW errors
UAS (unavailable seconds)
number of seconds without data transmission

3.4.4 Performance History

For line selection please click at line number above the table. The performance history shows
all errors which occurred in the 15-minute intervals over one day (24 hours).
38
Downloaded from
www.Manualslib.com
Modulation
1-pair resp.
2-wire
TC-PAM-16
TC-PAM-16
TC-PAM-32
manuals search engine
2-pair resp.
4-wire
192... 2304
384... 4608 576... 6912 768... 9216
192... 3840
384... 7680 576...11520 768...15360
768... 5696 1536...11392 2304...17088 3072...22784
BIG 10 Bridge
3-pair resp.
4-pair resp.
6-wire
8-wire
Version: 2013/04/15

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis