Herunterladen Inhalt Inhalt Diese Seite drucken

Direct Current - Weidmuller PTX800A Bedienungsanleitung

Zähler und totaliser mit zusatzfunktionen und grenzwertüberwachung
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Connections
Pin
Signal
1
Neutral / –e
2
Live / +e
3
Signal +
4
Signal –
5
0 V
6
Pulse
7
Reset count
8
Common
9
Security
10
Input – / 0 V
11
Input +
12
+24 V DC (out)
13
Normally Closed
14
Common
15
Normally Open
16
Normally Closed
17
Common
18
Normally Open
The PTX800A input circuits are rated category II (suitable for
measurements performed on the low voltage installation). They may
safely be floating with respect to local ground (i.e., subject to common
mode voltages) up to 50 V DC.
Symbols
The instrument labels use symbols in accordance with IEC61010-1:
- Consult documentation;
Insulated.
Power supply
Analogue output (optional)
Pulse output
Short to 8 to reset count
Short to 8 for setup mode
Inputs (according to set-up) in range:
Current: ±24.00 mA
Voltage: ±11.00 V
Alarm one
(optional)
Alarm two
(optional)

- Direct Current;

- Double
9

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis