Herunterladen Inhalt Inhalt Diese Seite drucken

Replacing The Power Cable; Cleaning, Maintenance And Ordering Of Spare Parts - EINHELL TE-AC 50 Silent Originalbetriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
6.3 Fitting the transport handle (9)
Screw the transport handle (9) to the compressor
as shown in fi gures 7 to 8.
6.4 Fitting the air fi lter (1)
Use a screwdriver to remove the transportation
cover from the air fi lter connection. Screw in the
supplied air fi lter (Fig. 9).
6.5 Mains connection
The motor is fitted with an overload switch
(Fig. 3/Item 15). If the compressor overloads,
the overload switch will switch off the equip-
ment automatically to protect the compressor
from overheating. If the overload switch trig-
gers, switch off the compressor using the ON/
OFF switch (8) and wait until the compressor
cools down. Then press the overload switch
(15) and restart the compressor.
Long supply cables, extensions, cable reels
etc. cause a drop in voltage and can impede
motor start-up.
At low temperatures below +5° C, sluggish-
ness may make starting difficult or impossib-
le.
6.6 On/Off switch (8)
To switch on the compressor, pull out the On/Off
switch (8).
To switch off the compressor, press the On/Off
switch (8) in again. (Fig. 2)
6.7 Adjusting the pressure:(Fig. 1.2)
You can adjust the pressure on the pressure
gauge (6) using the pressure regulator (7).
The set pressure can be taken from the quick-
lock coupling (5).
6.8 Setting the pressure switch
The pressure switch is set at the factory.
Cut-in pressure approx. 6 bar
Cut-out pressure approx. 8 bar

7. Replacing the power cable

Danger!
If the power cable for this equipment is damaged,
it must be replaced by the manufacturer or its
after-sales service or similarly trained personnel
to avoid danger.
Anl_TE_AC_50_Silent_SPK9.indb 18
Anl_TE_AC_50_Silent_SPK9.indb 18
GB
8. Cleaning, maintenance and
ordering of spare parts
Danger!
Disconnect the power plug before doing any
cleaning and maintenance work!
Warning!
Wait until the compressor has completely
cooled down. Risk of burns!
Warning!
Always depressurize the tank before carrying
out any cleaning and maintenance work.
Warning!
After use, always switch off the equipment
immediately and pull out the power plug.
8.1 Cleaning
Keep all safety devices, air vents and the
motor housing free of dirt and dust as far as
possible. Wipe the equipment with a clean
cloth or blow it with compressed air at low
pressure.
We recommend that you clean the device
immediately each time you have finished
using it.
Clean the equipment regularly with a moist
cloth and some soft soap. Do not use
cleaning agents or solvents; these could at-
tack the plastic parts of the equipment. Ensu-
re that no water can seep into the device. The
ingress of water into an electric tool increases
the risk of an electric shock.
You must disconnect the hose and any
spraying tools from the compressor before
cleaning. Do not clean the compressor with
water, solvents or the like.
8.2 Condensed water (Fig. 1)
Note:To ensure a long service life of the pressure
vessel (2), drain off the condensed water by ope-
ning the drain screw (11) each time after using.
Check the pressure tank for signs of rust and
damage each time before using. Do not use the
compressor with a damaged or rusty pressure
tank. If you discover any damage, please contact
the customer service workshop.
8.3 Safety valve (10)
The safety valve has been set for the highest per-
mitted pressure of the pressure tank.It is prohibi-
ted to adjust the safety valve or remove its seal.
- 18 -
15.07.2020 13:18:51
15.07.2020 13:18:51

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

40.206.20

Inhaltsverzeichnis