Herunterladen Inhalt Inhalt Diese Seite drucken

I Type (Initialized); In- / Output Description; Universal Output (Relays Output); Logic Selector - Cedes TOF/Spot Installationsanleitung

Vorschau ausblenden Andere Handbücher für TOF/Spot:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

TOF/Spot
1
Offset
150 mm
blue
brown
+U
SP
GND
blinking ≤ 30 s
Calibration
Figure 14:
Configuration T type - exchange of the polarity
2. Setting with the teach-in button
There is a button located at the back of the sensor. When
the teach-in button is pressed for at least 2 s, the LED blinks
for 30 s; the detection area (distance to the background
minus 150 mm (5.9 in) is saved and the LED dims. As soon
as a person or object enters the detection area, the sensor
switches the output.
The set switching distance can only be changed by pressing
the teach-in button again.
1
Offset
150 mm
Start-up:
dimmed or
bright
Push
Calibration
Figure 15:
Configuration T type with the teach-in button
Important:
 Be aware that the set switching level is always about
150 mm (5.9 in) above the background.
 A background within the maximal detection range
is used to calibrate the sensor. If there is none, an
object has to be used for simulating a background. A
calibration into nothingness does not work.
 When the power is switched off the sensor remembers
the last setting as the switching distance. This distance
can only be changed by doing the setting process
again.
6.5

I type (Initialized)

The I type has a specific detection range setting by factory
according customer request. Due to the potentiometer at
the rear of the sensor, a small adjustment of the operating
range is possible.
Important:
When setting with the potentiometer, use Figure 16 as the
settings are not printed on the sensor. Take a small screw
driver and turn the potentiometer to the required position.
8
2
3
blue
blue
brown
+U
GND
SP
GND
dimmed
dimmed
< 30 s
2
3
blinking ≤ 30 s
blinking
≥ 2 s
Release
4
brown
+U
SP
dimmed
Figure 16:
Tolerance adjustment (+/-) according sensor naming
Check & operation
Preset range
Tolerance
setting with
potentiometer
4
Figure 17:
Configuration - I type
7.

In- / Output description

dimmed
There are different possibilities of in- and outputs. Please
be aware that not all variants can be used with every type.
7.1

Universal output (relays output)

Check & operation
The TOF/Spot features a universal (relays) output. With
the help of the logic selector, the output signal can be
configured according to the controller requirements for
"normally open" or "normally closed" operation.
7.2

Logic selector

Output logic is set using the gray wire. The logic will be
defined by the power-up sequence. After the power-up the
logic will not change until the next power-up is made.
Output A and B
NC (normally closed)
Logic selector connected
to GND (0 V)
NO (normally open)
Logic selector connected
to U
SP
Figure 18:
Logic selector
Preset
5
6
range
Min.
Max.
tolerance
tolerance
dimmed
bright
LED bright
LED dimmed
5
6
dimmed
bright
English
Contact
closed
Contact
open
Contact
closed
Contact
open
© CEDES | V 4.0