11. Timing diagram

LED status
Power supply
Object detection
NC (normally closed)
Output
NO (normally open)
Output
Dynamic universal
output
Figure 24:
Timing diagram for relay output
Power-on time
Response time
Release time
Table 1:
General timing table

12. LED signal

LED status
Description
LED off
No power
LED dimmed red
No object detected
LED bright red
Object detected
LED blinking
Distance setting active
(C and T type only)
10
Off
Bright
X
X
t
1
Time
Value
t
1,000 ms
1
t
≤ 60 ms
2
t
≤ 60 ms
3
Dimmed
Bright
X
t
2
Voltage pin to GND
Output A and B
Voltage between pins
(relay)
Table 2:
General value table
X
On
Off
Object
No object
Closed
Open
Closed
Open
Closed
Open
t
3
Current
English
Value
-30 ... +30 V
-60 ... +60 V
< ±150 mA
© CEDES | V 4.0