Herunterladen Inhalt Inhalt Diese Seite drucken

I Type (Initialized); In- / Output Description; Universal Output (Relays Output); Logic Selector - Cedes TOF/Spot-Safety S Installationsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

TOF/Spot-Safety
1
Offset
150 mm
blue
brown
+U
SP
GND
blinking ≤ 30 s
Calibration
Figure 15:
Configuration T type - exchange of the polarity
2. Setting with the teach-in button
There is a button located at the back of the sensor. When
the teach-in button is pressed for at least 2 s and released,
the LED blinks for 30 s; the detection area (distance to the
background minus 150 mm (5.9 in) is saved and the LED
dims. As soon as a person or object enters the detection
area, the sensor switches the output.
The set switching distance can only be changed by pressing
the teach-in button again.
1
Commutation
150 mm
Démarrage :
obscurcie ou
brillant
Pousser
Calibrage
Figure 16:
Configuration T type with the teach-in button
Important:
 The sensor must be mounted in a way, that under
normal circumstances the button is not accessible.
 Be aware that the set switching level is always about
150 mm (5.9 in) above the background.
 A background within the maximal detection range
is used to calibrate the sensor. If there is none, an
object has to be used for simulating a background. A
calibration into nothingness does not work.
 When the power is switched off the sensor remembers
the last setting as the switching distance. This distance
can only be changed by doing the setting process
again.
6.4

I type (Initialized)

The I type has a specific detection range setting by factory
according customer request. Due to the potentiometer at
the rear of the sensor, a small adjustment of the operating
range is possible.
Important:
When setting with the potentiometer, use Figure 17 as the
settings are not printed on the sensor. Take a small screw
driver and turn the potentiometer to the required position.
© CEDES | V 4.0
2
3
blue
blue
brown
+U
GND
SP
GND
dimmed
dimmed
< 30 s
2
3
clignotante ≤ 30 s
clignotante
≥ 2 s
Lâcher
4
brown
+U
SP
dimmed
Figure 17:
Tolerance adjustment (+/-) according sensor naming
Check & operation
Preset range
Tolerance
setting with
potentiometer
4
Figure 18:
Configuration - I type
7.

In- / Output description

obscurcie
There are different possibilities of in- and outputs. Please
be aware that not all variants can be used with every type.
7.1

Universal output (relays output)

Test &
fonctionnement
The TOF/Spot-S features a universal (relays) output. With
the help of the logic selector, the output signal can be
configured according to the controller requirements for
"normally open" or "normally closed" operation.
7.2

Logic selector

Output logic is set using the gray wire. The logic will be
defined by the power-up sequence. After the power-up the
logic will not change until the next power-up is made.
Output A and B
NC (normally closed)
Logic selector connected
to GND (0 V)
NO (normally open)
Logic selector connected
to U
SP
Figure 19:
Logic selector
Preset
5
6
range
Min.
Max.
tolerance
tolerance
dimmed
bright
LED bright
LED dimmed
5
6
brillant
obscurcie
English
Contact
closed
Contact
open
Contact
closed
Contact
open
9

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis