Herunterladen Inhalt Inhalt Diese Seite drucken

Dynamic Universal Output; Installation; Mounting Of Snap-In Housing; Electrical Connection - Cedes TOF/Spot Installationsanleitung

Vorschau ausblenden Andere Handbücher für TOF/Spot:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

TOF/Spot
7.3

Dynamic universal output

The TOF/Spot features a universal (relay) output. In case
of the dynamic universal output this relay will switch with
a frequency of 1kHz. With the logic selector the signal can
be change to a frequency by object detected (logic selector
connected to U
, Figure 24)
SP
Contact open (U
)
SP
Output
signal
Contact closed (GND)
Figure 19:
Output signal if sensor connected according to
diagram in Chapter 9, Figure 23
Output A and B
Logic selector connected
to GND (0 V)
Logic selector connected
to U
SP
Figure 20:
Logic selector for dynamic universal output
8.

Installation

It is recommended to carry out the system installation
according to the following steps:
1. Check if the scope of delivery is complete.
2. Mark clearly that the modifying system is out of service
and switch off main power and door control unit.
3. The installation place needs to fulfill the criteria detailed
in Chapter 5.1.
4. Drill a hole at the required position (see drilling template
for flush and surface mounting).
5. If needed, mount the mounting bracket.
6. Snap in the sensor at the defined position.
7. Connect the TOF/Spot with the controller.
8.1

Mounting of snap-in housing

The mounting hole recommended for flush mounting is 30
to 31 mm. The sheet thickness cannot be greater 3 mm.
30 mm ± 0.5
(1.18 in ± 0.019 )
Figure 21:
Mounting of snap-in housing
© CEDES | V 4.0
9.
There are different possibilities according to supply power
and output chosen.
Relay output
Object detected
Figure 22:
Contact
open (U
)
SP
Important:
Contact
 The Output A and Output B are interchangeable.
closed (GND)
 Any unconnected (n.c.) wires have to be separated and
Contact
open (U
)
SP
Contact
closed (GND)
Dynamic universal output
Figure 23:
Important:
 The Output A and Output B are interchangeable.
 Any unconnected (n.c.) wires have to be separated and

10. Start-up

1. Switch on mains and power up the door control unit.
2. Check if LED lights up.
3. Check the distance setting and the reaction of the

Electrical connection

U
(10 ... 30 VDC)
SP
TOF/Spot
Output A
Output B
GND (0 V)
Not used
Logic selector
Solid-state relay output
isolated.
U
(10 ... 30 VDC)
SP
TOF/Spot
Output A
Output B
GND (0 V)
Not used
Logic selector
Dynamic universal output
isolated.
sensor, including the status LED, by placing a hand into
the detection area at different heights.
English
brown
black
green
blue
white
gray
brown
10 k
black
green
blue
white
gray
9

Werbung

Inhaltsverzeichnis