10. Start-up

1. Switch on mains and power up the door control unit.
2. Check if LED lights up.
3. Check the distance setting and the reaction of the sensor, including the status LED, by placing a hand into the
detection area at different heights.
4. Perform a test run with the controller using the test input.

11. Timing diagram

LED status
Power supply
Object detection
Test input
NC (normally closed)
Output
NO (normally open)
Output
Dynamic universal
output
Figure 25:
Timing diagram
Start-up time test input
Power-on time
Response time
Release time
Test response time
Test release time
Test time
Table 1:
General timing table

12. LED signal

LED status
Description
LED off
No power
LED dimmed red
No object detected
LED bright red
Object detected or test active
LED blinking
Distance setting active
(T type only)
LED blinking
No potentiometer value stored
(N Type only)
© CEDES | V 4.0
Off
Bright
Dimmed
X
X
X
t
1
t
2
Time
Value
t
< 200 ms
1
t
1,000 ms
2
t
≤ 60 ms
3
t
≤ 60 ms
4
t
5 ms
5
t
≤ 60 ms
6
t
> 60 ms
7
Bright
Dimmed
X
t
t
3
4
Test input
Output A and B
(relay)
Table 2:
General value table
Bright
X
X
TEST
t
t
5
6
t
7
HIGH
LOW
Voltage pin to GND
Voltage between pins
Current
English
On
Off
Object
No object
Inactive
Active
Closed
Open
Closed
Open
Closed
Open
Value
10 VDC ... U
SP
0 ... 3 VDC
-30 ... +30 V
-40 ... +40 V