Problem
Burner flame is low.
Note: Do not operate the
appliance below 5 °C
(40 °F).
Emitter glows uneven.
Note: Bottom 2.5 cm of
emitter normally does
not glow.
Carbon build-up
Thick black smoke
Cause / Condition
Gas pressure is low.
Outdoor temperature
is higher than 5 °C
(40 °F) and tank is less
than 25 % full.
Supply hose is bent or
kinked .
The control knob is in
"HIGH" position.
Gas pressure is low.
Base is not on a level
surface.
The appliance is not
level.
Dirt or film on reflector
and emitter.
Blockage in burner.
Solution
Replace gas cylinder.
Replace gas cylinder
Straighten hose and
perform leak test on
hose.
Turn control knob to
"OFF", let it cool to
room temperature
and check burner and
orifices for blockage
Replace gas cylinder.
Place the appliance on
a level surface
Level the appliance.
Clean reflector and
emitter.
Turn control knob to
"OFF", let it cool to
room temperature,
remove blockage and
clean burner inside and
outside.