Troubleshooting guide

Problem
The display shows the
message O-L
The display shows the
high dash on the upper
display
The display shows the
underscore on the lower
display.
The number of decimals
is incorrect
Serial communication is
not working properly.
The semi-automatic
zero function does not
work.
The semi-automatic tare
function does not work.
Possible cause
The acquired weight is not detectable
because the cell is absent or connected
incorrectly
The acquired weight cannot be repre-
sented because it exceeds the five
available digits or is greater than the
capacity of the cells.
The acquired weight cannot be repre-
sented because it is negative beyond
-9999.
The correct division value was not se-
lected.
The installation was not carried out cor-
rectly.
The selection of the serial interface op-
eration mode is incorrect.
The gross weight exceeds the semiau-
tomatic zero action limit.
The weight does not stabilize
The gross weight is negative or ex-
ceeds / has reached the maximum ca-
pacity value.
The weight does not stabilize
Pagina –
Check the connection of the load cell
Select the correct division value in the
main menu
Check the connections as described in
the installation manual.
Select settings appropriately.
To restore the zero it is necessary to
calibrate the weight.
Wait for the weight to stabilize or adjust
the weight filter parameter.
Check the gross weight
Wait for the weight to stabilize or adjust
the weight filter parameter.