DVR1C1161 | Installation Manual | Chapter 2

2.3 Rear panel

2.3.1 Power

Connect the power suppy cable to the power socket at
the rear of the unit. Use the power switch to switch the
unit ON or OFF.

2.3.2 RS232 serial connector

Connect D-Sub 9-pin connector to the RS232 port if
you want to control the unit remotely.

2.3.3 IR remote control eye connector

If the remote control IR receiver window at the front is
hidden from view (if the unit is mounted in a cupboard),
connect the optionally available extension IR cable to
the remote control connector. Position the receiver eye
so that it is in line-of-sight of the remote control unit.

2.3.4 LAN connector

To connect the unit to a network use the RJ-45 LAN
connector at the rear of the unit.

2.3.5 Alarm connections

The ALM-IN and ALM-RST inputs can be set to
Normally Open (N.O.) or Normally Closed (N.C.) in
the Alarm record menu.
GND:
Ground connection.
ALM-IN:
Apply a signal* here to start alarm
recording.
ALM-RST:
Apply a signal* here to stop alarm
recording.
Power switch
Power
AC 100-240
100-240 Vac
Bosch Security Systems | 2004-6
All manuals and user guides at all-guides.com
Video
Audio
Mux main
Monitor In
S-Video
In
In
Off
In1
In2
Out1
Out2
Monitor Out
Out
Out 1
REC:
A high level external recording request
signal* applied to this pin starts
recording. When the signal drops to low,
recording stops.
NC1, NC2:
No connections.
* Signal
- switching voltage High: > 2 Vdc
- switching voltage Low: < 0.5 Vdc
- max. input voltage: 12 Vdc
Alarm inputs
The alarm output signals are:
GND:
Ground connection.
ALM-NC**:
When an alarm occurs, the connection
between this pin and ALM-COM is
open. Otherwise it is closed.
ALM-NO**:
When an alarm occurs, the connection
between this pin and ALM-COM is
closed. Otherwise it is open.
ALM-COM**: Alarm common contact.
VEXT:
Synchronization signal for multiplexer.
Output voltage: 5 Vdc
Output current: 100mA
DISKFULL:
Disk full alarm output signal.
Output voltage: 5 Vdc
Output current: 100mA
NC3, NC4:
No connections.
* * contact voltage max: 24 Vdc
max. switching current: 2A dc
IR remote
control eye
RS-232
connector
connector
RS 232
Remote Control
Looping out
Out 2
GND
VEXT
Alarm connector
EN | 8
Alarm outputs
LAN
Network connector

Werbung