F. UV LAMP REPLACEMENT & QUARTZ TUBE MAINTENANCE
The High Output UV bulb in your Elektra UV unit is a useful life of approximately 9000 hours of operation
(except in the case of repeated lightings where its lifespan could be lower).
The replacement of lamp after 9000 hours is obligatory.
The quartz tube should be removed, inspected and cleaned from the reactor every year and at each
replacement of lamp.
Reminder: Do not touch the UV bulb glass with your bare hands.
That can shorten its life. Grasp the bulb on the white ceramic prong end
cotton cloth or clean cotton gloves to handle the UV bulb. (If you have touched the bulb with
your bare hands, you must wipe the bulb glass off with spirit vinegar using a clean soft
cotton cloth)
1
Allow the ultraviolet lamp to cool for at least 30 minutes before handling.
2
Remove the plastic electrical enclosure bonnet by unscrewing the four mounting screws.
3
4
Remove and throw the transport joints (between the lamp and the quartz tube) if they are still present
Carefully place the removed bulb in a safe location while cleaning the quartz tube.
5
6
The quartz tube exterior can normally be cleaned by using acid or spirit vinegar or
pH minus (liquid) with weak concentration. (ratio of 4 parts water to one part acid)
7
8
Install and tighten the black plastic mounting gland. Do not overtighten.
9
10
Without forcing, plug the UV lamp to 4 pin connector (attached to the ballast wires).
11
Reinstall the plastic electrical enclosure bonnet by screwing the 4 mounting screws
12
13
Verify that the bulb is lit by viewing the glow of the bulb through the clear plastic union.
V5 Elektra E et ES Anglais.doc
Marque, Modèles et Brevets déposés - Produits exclusifs
STOP THE FILTRATION.
BLEED the Elektra UV unit.
Unplug the UV lamp by grasping the 4-pin connector
(attached to the ballast wires).
SLOWLY pull the UV lamp out of the quartz tube
(by grasping the bulb on the white ceramic prong end).
Unscrew the black plastic mounting gland.
Grasp the quartz tube and pull straight up.
Remove the sealing gasket (lip seal).
Carefully inspect the cleaned quartz tube for cracks.
Do not use abrasive cleaners.
Change the quartz tube if necessary.
Seat the quartz tube DELICATELY into the receptor up to backstop
Take a new sealing gasket (lip seal).
(Put a new sealing gasket at each change of lamp)
Place it on the end of quartz tube (lip downwards).
SLOWLY lower the bulb down into the quartz tube.
Power up the filtration.
(without dropping it).