Gate Control PRO Quick guide
- A control call/command only opens the gate. Closing should be done
automatically by the gate automation control board.
Control mode 2:
- For one or two gates, or one gate with two opening options (partial/ total
opening).
- Both outputs are normally open (NO).
- Both outputs are controlled by call with caller identification as configured
(OUT1 only, OUT2 only, or both at the same time).
- You can control both outputs separately with the mobile app.
- Output control permission can be configured separately for each user and
each output.
- Gate position limit switches can be connected to inputs IN3 (for gate No. 1)
and IN4 (for gate No. 2).
- A control call/command only opens the gate. Closing should be done
automatically by the gate automation control board.
Control mode 3:
- For single-gate automations
that
require
opening and closing on the
same input.
- Opening and then closing by a
single call/control command.
- Output OUT1 is normally open
(NO), while OUT2 is normally
closed (NC).
- Output OUT1 is used to
control the gate, while OUT2
is
used
to
photocell
sensor
thereby providing an option to
keep the gate open for the
configured period of time.
- Keeping the gate open permanently on a second call/control command.
- The gate position limit switch can be connected to input IN3.
triggers
for
interrupt
the
circuit,
3