Herunterladen Inhalt Inhalt Diese Seite drucken

Commissioning Of The Receiver - ICP ICARUS Serie Handbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

RX HEAVY
4.2 LED-STATUSANZEIGE
General:
50ms on
off
slow flashing
normal flashing
fast flashing
constantly on
flash sequence
(e. g. 3×)
POWER LED
off
No power supply
constantly on (green)
Emergency stop switch on receiver not pressed
slow flashing (green)
Emergency stop switch on receiver pressed
fast flashing (grün)
Learning mode active (description see 4.11)
flash sequence (red)
Error (for description see 4.9)
ACTIVE LED
constantly on (green)
System activated (emergency stop switch of the transmitter
not pressed (TX HEAVY) or the power switch is ON (TX MINI))
slow flashing (green)
System deactivated (emergency stop switch of
the trans mitter pressed (TX HEAVY) or the power switch
is OFF (TX MINI))
DATA LED
on (green)
Data transfer is taking place
(key pressed on transmitter (ID of the transmitter recognised))
on (red)
Data transfer is taking place
(key pressed on transmitter (ID of the transmitter not recognised))
off
No data transfer (no key pressed on the transmitter)
on (green)
Transmitter successfully logged on
(in learning mode when key is pressed)
on (red)
Transmitter successfully logged off
(in learning mode when key is pressed)
118
RF LED
on (green)
Any radio signal detected
off
No radio signal detected
Output LEDs
LED 1 (red) on
Output 1 active
LED 2 (green) on
Output 2 active
LED 3 (green) on
Output 3 active
LED 4 (grün) on
Output 4 active
LED 5 (green) on
Output 5 active
LED 6 (green ) on
Output 6 active
LED 7 (red) on
Output 7 active
LED 8 (green) on
Output 8 active
Only 8 outputs are displayed.
flashing
Shortcut of the relevant output

4.3 CoMMISSIoNING of THE RECEIVER

Supply operating voltage to the receiver (9-30V DC) and
log on the transmitter as described (4.11).
RX HEAVY
119