1.8 TRANSMITTER fAULT fINDING

YES
POWER LED lights up
BATTERY LED is flashing
after switching on
NO
YES
– Switch off transmitter
– Change the batteries
– Power switch on
Does the transmitter work now?
NO
The transmitter is defective.
Please contact the supplier.
100
NO
When a button is
pressed the POWER
LED flashes quickly
NO
– Switch off transmitter
– Wait for 10 seconds
– Power switch on
Does the transmitter work now?
NO
If the status LED flashes, see description in 1.9!
If the transmitter only works over short distances, please proceed as follows:
I.
Ensure that the distance between the transmitter
and receiver is not greater than 50 metres.
II.
Ensure that there are as few objects as possible, particularly
metallic objects, between the transmitter and the receiver.
III. If you are surrounded by a metallic grating or another
heavy metallic structure, please leave these surroundings.
IV. Check if there are transmission masts in the immediate vicinity,
which could lead to faults, and if necessary leave this area.
V.
Check if there are cables in the immediate vicinity carrying
high voltage or current and leave these surroundings if necessary.
If the transmitter still does not work correctly after carrying out these steps, please
contact your supplier.

1.9 ERRoR CoDES AND REPAIR

In case of system malfunctions, the STATUS LED shows which error
has occurred using an error code. The STATUS LED flashed x times followed
by a short pause, then the STATUS LED flashes x times again etc...
If you count how many times the STATUS LED flashes in each interval,
you can diagnose the error using the following listing.
The error is specified in this case only for diagnostic purposes. They are internal
errors that cannot be influenced by the operator without authorisation. To clear
the error display, switch off the remote control using the POWER switch,
wait 5 seconds and switch it on again.
LED is flashing: Bedeutung:
3 times
No connection between the controller and the radio module
4 times
Incorrect synchronisation of the PLL
5 times
Serial number error (internal)
6 times
Connection between the controller and the radio module deactivated
flash sequence (e.g. 3 times)