Gouging torch
Fault
Gouging torch becomes
too hot
Troubleshooting
Tab. 8
11 Disassembly
NOTICE
• Please also consult the operating instructions for the welding
components, such as power source, compressed air line.
• If the measures described below are not successful, please consult your
dealer or the manufacturer.
Cause
• Power connections loose on the
burner side and toward the
workpiece
• Insufficient compressed air
• Carbon electrode too short
• Load too high
DANGER
Risk of injury due to unexpected start-up
The following instructions must be adhered to for the entire duration of
maintenance, servicing, disassembly and repair work:
• Switch off the power source.
• Close the compressed air supply.
• Switch off the entire welding system.
• Disconnect the mains plug.
NOTICE
• Disassembly may only be carried out by qualified personnel (in Germany
see TRBS 1203).
• Please also consult the operating instructions for the welding components,
such as power source, compressed air line.
• Observe the information provided in the following chapter:
 8 Putting out of operation on page EN-11.
1 Cut off the hose and power cord.
2 Remove the parts to be disconnected.
11 Disassembly
Troubleshooting
• Check and tighten
• Completely open valve
• Check compressed air supply
• Correct clamping length
• Observe maximum load and
duty cycle
EN - 13