Herunterladen Inhalt Inhalt Diese Seite drucken

Looper Thread Control; Looper Thread Take-Up Setting; Greiferfadenaufnehmer-Einstellung - Union Special BC100 Originalbetriebsanleitung, Wartungsanleitung Und Illustriertes Teileverzeichnis

Hochleistungs-nähmaschinen zum schliessen gefüllter säcke
Inhaltsverzeichnis

Werbung

LOOPER THREAD CONTROL

1. Set the cast off edge of looper thread take-up to be 2.000"
(51 mm) from the outside of the looper thread take-up
shaft.
2. Set the center line of the take-up eyelet hole to be 1.850"
(47 mm) from the outside of the looper thread take-up
shaft.
3. Set the edge of the looper thread take-up so that the take-
up eyelet hole is just free when the take-up is at the end of
its stroke.

LOOPER THREAD TAKE-UP SETTING

The looper thread should cast-off at the high point of the cam
of the thread take up when the tip of the needle is within .040"
(1 mm) of the bottom of the looper blade. Increase the amount
of the looper thread when lengthening the stitch by raising the
cast-off cam in its slot. Recheck the cast-off setting.
Downloaded from
www.Manualslib.com
manuals search engine
GREIFERFADENKONTROLLE
1.
Stellen Sie die Abzugskante des Greiferfadenabzugs bis
Außenseite Greiferfadenabzugswelle auf das Maß 51mm
ein.
2.
Stellen Sie die Mitte der Abzugsöse bis Außenseite
Greiferfadenabzugswelle auf das Maß 47 mm ein.
3.
Stellen Sie die Kante des Greiferfadenabzugs in Hub
ende so ein, daß die Abzugsöse gerade frei ist.

GREIFERFADENAUFNEHMER-EINSTELLUNG

Der Greiferfaden soll dann am höchsten Punkt der Kurve des
Fadenaufnehmers „abspringen", wenn die Spitze der Nadel
innerhalb 1 mm oberhalb der Unterkante der Greiferklinge
steht. Sie vergrößern die Greiferfadenmenge - bei größerer
Stichlänge - durch Höherstellen des Fadenaufnehmers in
seinem Aufnahmeschlitz. Prüfen Sie nochmals die
Greiferfadenkontrolle.